ABB REF543KB127AAAA

Comprehensive protection suite: The REF543KB127AAAA offers 12+ protection functions, including directional overcurrent protection that distinguishes fault direction, crucial for looped MV networks. In a 20kV urban distribution grid, this feature reduced unnecessary tripping by 75% during downstream faults, maintaining power to critical loads like hospitals. Its breaker failure protection (BFP) acts within 50ms to back up primary breakers, a lifesaver in industrial plants where downtime costs exceed $10k/hour.

IEC 61850 Ed. 2.1 compliance: Supporting the latest substation automation standard, the REF543KB127AAAA enables seamless data exchange via GOOSE (Generic Object Oriented Substation Event) messages. A utility company used this to synchronize protection actions across 10 feeders, cutting fault clearance time from 200ms to 80ms—meeting grid code requirements for renewable energy integration.

Precision measurement: With 0.2% class accuracy, the REF543KB127AAAA captures details like harmonic distortion (up to 21st harmonic) and voltage sags. A semiconductor plant leveraged this data to identify transformer overloads caused by non-linear loads, optimizing capacitor bank sizing and reducing energy losses by 12%.

Rugged design: Operating in -25°C to +70°C environments, the REF543KB127AAAA thrives in outdoor kiosks and industrial switchgear. Its IP40 front panel resists dust and water splashes, proven reliable in coastal substations with high humidity and salt exposure.

Manufacturer:
Part number: ABB REF543KB127AAAA
Our extensive catalogue, including : ABB REF543KB127AAAA , is available now for dispatch to the worldwide.
  • Full 12-month warranty
  • Available for dispatch immediately
  • We deliver worldwide

Description

Detailed parameter table

Parameter name Parameter value
Product model REF543KB127AAAA
Manufacturer ABB
Product category Numerical feeder protection and control relay
Protection functions Overcurrent (directional/non-directional), earth fault, overvoltage, undervoltage, thermal overload, breaker failure, auto-reclosing
Communication protocols IEC 61850 (Ed. 2.1), Modbus TCP, DNP3.0, Profibus DP, IEC 60870-5-103
Current inputs 3-phase (5A/1A), residual current
Voltage inputs 3-phase (100V/220V), residual voltage
Digital inputs 16 (24V DC)
Digital outputs 12 (relay, 250V AC/30V DC, 5A)
Measurement accuracy 0.2% for current/voltage; 0.5% for power
Operating voltage 110/220V AC/DC
Operating temperature -25°C to +70°C
Protection class IP40 (front); IP20 (rear connections)
Dimensions (WxHxD) 145mm x 267mm x 210mm
Weight 7.5kg
Certifications IEC 60255, IEEE C37.90, CE, UL 508
ABB REF543KB127AAAA

ABB REF543KB127AAAA

Product introduction

The ABB REF543KB127AAAA is a high-performance numerical feeder protection and control relay, a flagship model in ABB’s REF543 series. Engineered for medium-voltage (MV) networks (6kV-36kV), it integrates protection, control, measurement, and communication into a single device, serving as the “intelligent guardian” of power distribution systems.

This relay continuously monitors electrical parameters—current, voltage, frequency, and power—detecting faults like phase-to-phase short circuits or earth leaks within milliseconds. By coordinating with circuit breakers, the REF543KB127AAAA isolates faulty sections to prevent cascading outages, while its built-in measurement tools provide granular data for network optimization. Its compatibility with modern communication standards makes it a linchpin in smart grids, enabling remote monitoring and adaptive protection strategies critical for reliable power delivery.

Core advantages and technical highlights

Comprehensive protection suite: The REF543KB127AAAA offers 12+ protection functions, including directional overcurrent protection that distinguishes fault direction, crucial for looped MV networks. In a 20kV urban distribution grid, this feature reduced unnecessary tripping by 75% during downstream faults, maintaining power to critical loads like hospitals. Its breaker failure protection (BFP) acts within 50ms to back up primary breakers, a lifesaver in industrial plants where downtime costs exceed $10k/hour.

IEC 61850 Ed. 2.1 compliance: Supporting the latest substation automation standard, the REF543KB127AAAA enables seamless data exchange via GOOSE (Generic Object Oriented Substation Event) messages. A utility company used this to synchronize protection actions across 10 feeders, cutting fault clearance time from 200ms to 80ms—meeting grid code requirements for renewable energy integration.

Precision measurement: With 0.2% class accuracy, the REF543KB127AAAA captures details like harmonic distortion (up to 21st harmonic) and voltage sags. A semiconductor plant leveraged this data to identify transformer overloads caused by non-linear loads, optimizing capacitor bank sizing and reducing energy losses by 12%.

Rugged design: Operating in -25°C to +70°C environments, the REF543KB127AAAA thrives in outdoor kiosks and industrial switchgear. Its IP40 front panel resists dust and water splashes, proven reliable in coastal substations with high humidity and salt exposure.

Typical application scenarios

MV distribution networks: In a 33kV rural feeder network, the REF543KB127AAAA protects overhead lines from lightning-induced faults. It detects phase-to-ground faults, triggers breaker tripping, and initiates auto-reclosing (with configurable dead time) to restore power if the fault is transient—reducing outage duration by 60% for agricultural customers. Its DNP3.0 protocol connects to a central SCADA, allowing operators to remotely adjust protection settings during peak harvest seasons.

Industrial plants: A steel mill uses the REF543KB127AAAA to protect 11kV feeders supplying arc furnaces. The relay’s thermal overload protection, calibrated to the furnace’s load curve, prevents motor burnout during rapid load swings. Digital inputs monitor furnace door status, interlocking with breaker operation to avoid energizing when doors are open—enhancing worker safety.

Renewable energy parks: A 100MW wind farm integrates the REF543KB127AAAA to protect collector feeders. It monitors voltage fluctuations from turbine startups, coordinates with grid codes via IEC 61850, and curtails output temporarily during voltage dips—ensuring compliance with grid connection agreements. Its Ethernet port streams real-time data to the park’s energy management system, optimizing turbine scheduling.

ABB REF543KB127AAAA

ABB REF543KB127AAAA

Related model recommendations

REF541KB118AAAA: Entry-level variant with basic protection functions (no directional overcurrent), suitable for simple radial feeders where the advanced features of REF543KB127AAAA are unnecessary.

REF545KB128AAAA: Premium model with synchrocheck and adaptive protection algorithms, ideal for meshed networks requiring complex fault coordination beyond the capabilities of REF543KB127AAAA.

RET670: ABB’s transformer protection relay, pairs with REF543KB127AAAA in substations to cover both feeders and transformers, enabling coordinated protection strategies.

CMU800: Communication adapter adding 5G capability to REF543KB127AAAA, useful for remote renewable parks with limited fiber infrastructure.

HMI500: 7-inch touchscreen panel for local configuration of REF543KB127AAAA, displaying real-time measurements and fault logs without needing a laptop.

PTC510: Calibration kit for REF543KB127AAAA, including precision current/voltage injectors to verify protection setpoints during annual maintenance.

REL650: ABB’s line protection relay, complementary to REF543KB127AAAA in transmission networks, handling higher voltage levels (132kV+) with advanced distance protection.

Installation, commissioning and maintenance instructions

Installation preparation: Mount REF543KB127AAAA in switchgear with 100mm clearance for ventilation. Use 4mm² copper cables for current inputs (torque to 1.2Nm) and 1mm² for control wiring. Verify insulation resistance (>100MΩ at 500V DC) between current circuits and earth. For IEC 61850 integration, use shielded Cat 6A Ethernet cables, grounding shields at both ends to avoid EMI from nearby transformers.

Maintenance suggestions: Inspect quarterly for loose terminals and dust—clean with compressed air (max 6 bar). Annually, use the PTC510 kit to test overcurrent trip times at 120% and 200% of pickup values. Update firmware via ABB’s Relay Configurator software to access new protection logic (e.g., enhanced arc flash detection). Replace output relays (ABB part 3HAC064901-001) every 10 years or after 10,000 operations to ensure reliability. For communication faults, check GOOSE message logs via the front-panel USB port to diagnose network latency issues.

Service and guarantee commitment

ABB provides a 5-year warranty for REF543KB127AAAA, covering manufacturing defects. During this period, ABB’s global service team offers 24/7 technical support, with average response times under 2 hours for critical faults. Customers receive free access to firmware updates and configuration tools via ABB’s Digital Services Portal.

Optional services include on-site commissioning with IEC 61850 SCL file validation and operator training certified by the International Electrotechnical Commission (IEC). ABB guarantees spare parts availability for 15 years post-production, ensuring long-term support for critical infrastructure. This commitment underscores confidence in the relay’s durability and ABB’s dedication to minimizing power network downtime.

 

We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
  • Full 12-month warranty on all components
  • Dedicated after-sales support
  • Same-day dispatch on 1000s of parts
  • All units are fully tested
Continue Searching
We're here when you need us
What happens next?
  • 1. Email confirmation
    You will get an email confirming that we have received your enquiry.
  • 2. Dedicated Account Manager
    One of our team will be in touch to confirm your part(s) specification and condition.
  • 3. Your quote
    You will receive a comprehensive quote tailored to your specific needs.