Description
Detailed parameter table
Parameter name | Parameter value |
Product model | 135462-01 |
Manufacturer | Bently Nevada (a division of GE Vernova) |
Product category | Signal conditioning amplifier for high-temperature sensors |
Input type | Piezoelectric accelerometers, charge-output sensors |
Output signals | 4-20mA, 0-10V DC, and buffered charge output |
Gain range | 1-1000 mV/pC (configurable) |
Frequency response | 0.1Hz to 10kHz (-3dB) |
Operating voltage | 24V DC ±10% |
Operating temperature | -40°C to 70°C (-40°F to 158°F) |
Isolation rating | 2.5kVrms (input to output/ground) |
Physical dimensions | 100mm x 60mm x 25mm (width x height x depth) |
Mounting method | DIN rail mount (35mm standard) |
Weight | 150g (5.3oz) |
Compliance | CE, RoHS, ATEX Zone 2, IECEx |
Compatible sensors | 330703-000-070-10-02-05, 330980 series accelerometers |
Calibration tool | 128240-01 verification tool compatible |
BENTLY 135462-01
Product introduction
The 135462-01 from Bently Nevada is a high-performance signal conditioning amplifier, engineered to process and convert signals from charge-output sensors into standardized industrial outputs for machinery monitoring systems. As a critical interface component in harsh environment monitoring setups, this compact amplifier bridges the gap between high-temperature accelerometers like the 330703-000-070-10-02-05 and control systems, ensuring accurate vibration data transmission even in electrically noisy industrial environments.
Designed for flexibility and reliability, the 135462-01 accepts charge signals from piezoelectric sensors and converts them into industry-standard 4-20mA or 0-10V outputs, while also providing a buffered charge output for redundant systems. Its rugged construction and DIN rail mounting make it ideal for installation in control cabinets near high-temperature machinery, such as turbine enclosures and process pumps. When paired with compatible sensors, termination panels like the 146031-02, and calibration tools such as the 128240-01, it forms a complete signal processing solution for demanding vibration monitoring applications.
Core advantages and technical highlights
Multi-output versatility: The 135462-01 provides three simultaneous output options—4-20mA, 0-10V DC, and buffered charge output—enabling flexible integration with various monitoring systems. This versatility allows connection to PLCs, DCS, data loggers, and specialized vibration analyzers using a single amplifier, reducing system complexity and equipment costs. The 4-20mA output is particularly valuable for long-distance transmission in noisy industrial environments.
Configurable signal processing: With a programmable gain range of 1-1000 mV/pC, the amplifier adapts to different sensor sensitivities and measurement ranges, making it compatible with a wide variety of piezoelectric sensors including the 330703-000-070-10-02-05. Its adjustable low-pass and high-pass filters allow optimization for specific machinery types, ensuring accurate capture of relevant vibration frequencies while rejecting unwanted noise.
Enhanced noise immunity: Featuring 2.5kVrms isolation between inputs and outputs, the 135462-01 provides superior protection against ground loops, voltage transients, and electromagnetic interference (EMI) common in industrial environments. The amplifier’s differential input design and low-noise circuitry further minimize signal degradation, ensuring that subtle vibration signals from high-temperature sensors remain intact for accurate analysis.
Compact industrial design: The amplifier’s compact DIN rail mount design (100mm x 60mm x 25mm) saves valuable cabinet space, while its rugged construction withstands temperature extremes (-40°C to 70°C) and vibration. The sealed housing protects internal components from dust and moisture, ensuring reliable operation in harsh control cabinet environments. LED status indicators provide quick visual verification of power and signal presence.
Seamless system integration: Designed specifically to work with Bently Nevada’s high-temperature sensors like the 330703-000-070-10-02-05, the amplifier ensures optimal signal transfer and measurement accuracy. Its compatibility with the 128240-01 calibration tool allows for easy verification of the entire sensor-amplifier chain, ensuring measurement integrity from the sensor to the control system.
Typical application scenarios
In gas turbine power plants, the 135462-01 is installed in control cabinets near turbine enclosures, processing signals from 330703-000-070-10-02-05 accelerometers monitoring exhaust bearings. The amplifier converts the sensor’s charge output into a 4-20mA signal that travels safely to the plant’s 1900/65A-01-01-01-00-00 controller, while the buffered charge output connects to a dedicated vibration analyzer for advanced diagnostics. Its isolation protection prevents electrical noise from turbine controls from corrupting vibration signals.
Within petrochemical refineries, the amplifier processes signals from accelerometers monitoring high-temperature pumps and compressors in hazardous areas. Mounted in explosion-proof control cabinets, the 135462-01 converts charge signals into noise-resistant 4-20mA outputs that connect to 146031-02 termination panels. Its ATEX certification ensures safe operation in Zone 2 environments, while the configurable filters help distinguish between normal process vibration and early fault signatures.
In steel manufacturing facilities, the 135462-01 provides signal conditioning for sensors monitoring rolling mill drives and furnace fans. The amplifier’s wide gain range accommodates different sensor sensitivities throughout the facility, while its compact size allows installation in space-constrained control cabinets near production lines. Maintenance teams use the 128240-01 tool to verify the entire measurement chain, ensuring accurate data for both protection and predictive maintenance programs.
BENTLY 135462-01
Related model recommendations
135462-02: A dual-channel variant of the 135462-01 for monitoring multiple sensor points.
330703-000-070-10-02-05: High-temperature accelerometer optimally paired with this amplifier.
128240-01: Calibration verification tool for validating sensor-amplifier performance.
146031-02: 32-channel termination panel for centralized connection of amplified signals.
00E04600EFD8: High-temperature cable connecting sensors to the 135462-01.
1900/65A-01-01-01-00-00: Machinery protection controller that accepts amplifier outputs.
106M1081-01: Mounting adapter for sensors connected to this signal conditioner.
Installation, commissioning and maintenance instructions
Installation preparation: Before installing the 135462-01, ensure the DIN rail is securely mounted in a clean, dry control cabinet with adequate ventilation. Verify the 24V DC power supply is properly regulated and fused. Plan sensor cable routing using shielded twisted-pair cables like the 00E04600EFD8 to minimize EMI. For hazardous area installations, confirm the cabinet meets ATEX Zone 2 requirements.
Mounting procedure: Secure the 135462-01 to the DIN rail, ensuring proper alignment and secure engagement. Connect the 24V DC power supply, observing correct polarity. Wire the charge-output sensor to the input terminals, ensuring proper shield grounding at the amplifier end. Connect the desired outputs (4-20mA, 0-10V, or buffered charge) to the control system or termination panel, using twisted-pair cable for analog outputs. Configure gain and filter settings using the front-panel DIP switches or software interface.
Commissioning verification: After installation, use the 128240-01 calibration tool to verify the entire measurement chain. Connect the tool to the sensor mounting surface, generate known vibration levels, and confirm the amplifier’s outputs correspond accurately to the applied stimulus. Adjust gain settings if necessary to optimize signal levels for the specific application and sensor sensitivity.
Maintenance suggestions: Inspect the 135462-01 quarterly for loose connections, dust accumulation, or signs of overheating. Clean dust from ventilation slots using compressed air to maintain thermal performance. Verify output signals using a calibrated meter, comparing them to expected values during normal machinery operation. Perform annual verification using the 128240-01 tool to ensure gain stability and filter performance. Check DIP switch settings periodically to confirm they remain configured correctly.
Service and guarantee commitment
The 135462-01 is backed by a 3-year warranty covering defects in materials and workmanship under normal operating conditions. Bently Nevada’s global technical support team provides expert assistance for configuration, integration, and troubleshooting, with 24/7 availability for critical system issues.
We offer detailed configuration guides and application notes for optimizing the 135462-01 with compatible sensors like the 330703-000-070-10-02-05. Training programs cover amplifier setup, signal conditioning principles, and verification procedures using the 128240-01 tool. Calibration services are available to ensure measurement accuracy and compliance with industry standards. Backed by Bently Nevada’s expertise in industrial signal processing, the 135462-01 delivers reliable performance for converting critical vibration signals in demanding monitoring applications.
Full 12-month warranty on all components
Dedicated after-sales support
Same-day dispatch on 1000s of parts
All units are fully tested
- 1. Email confirmation
You will get an email confirming that we have received your enquiry. - 2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition. - 3. Your quote
You will receive a comprehensive quote tailored to your specific needs.