GE IC693CPU374-JY | Single-Slot CPU Module – Series 90-30 Controller

  • Model:​ IC693CPU374-JY
  • Brand:​ GE Fanuc (Emerson Automation)
  • Series:​ Series 90-30
  • Core Function:​ Central processor executing control logic, managing I/O, and handling dual Ethernet communications for Series 90-30 PLCs
  • Type:​ Single-Slot CPU Module
  • Key Specs:​ 133 MHz AMD SC520 | 0.15ms scan time | 240KB user memory
  • Condition:​ New Original (New Surplus) — not refurbished ⚠️ EOL — limited stock remaining
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
The listed price is not final; the actual selling price is negotiable based on current market conditions.

Description

Product Introduction

The -JY suffix denotes another specific firmware/hardware revision in the IC693CPU374 family—I’ve encountered these in food processing plants where network stability trumps all other considerations. This single-slot controller represents the high-performance tier within the Series 90-30 lineup .Honestly, the dual-port internal switch design eliminates external switches in daisy-chain topologies—a clever choice for network redundancy without extra hardware. The 133 MHz AMD SC520 processor delivers 0.15 ms scan time per 1K Boolean instructions, though your mileage may vary with complex PID loops .

 

Key Technical Specifications

Parameter Value
Module Type Single-Slot CPU Module (32-bit processor)
Processor AMD SC520 @ 133 MHz
Memory 240 KB battery-backed RAM (user program/data)
Scan Time 0.15 ms per 1K Boolean logic instructions (typical)
I/O Capacity 2048 discrete I/O points; 32,640 analog I/O words (max)
Communication Ports 2x RJ-45 Ethernet (10/100 Mbps auto-sensing)
Serial Interface RS-485 via power connector (SNP/SNPX protocols)
Power Consumption 7.4 W @ 5 V DC (from PLC backplane)
Operating Temperature 0°C to 60°C (32°F to 140°F); storage: -40°C to 85°C
Network Protocols Modbus TCP/IP, SRTP, EGD, Device Level Ring topology support
Baseplate Support 8 baseplates maximum (1 CPU + 7 expansion)
Certifications UL508, C-UL, CE
GE IC693CPU374

GE IC693CPU374

 

Quality Control Process (SOP Transparency)

Here’s how we verify the GE IC693CPU374-JY. We use Fluke 115 for electrical tests and a dedicated Series 90-30 test rack with dual Ethernet simulation.

  1. Incoming Verification:​ Trace serials against OEM lists, verify -JY suffix denotes specific firmware revision, inspect dual RJ-45 ports for physical damage, audit accessories (none included).
  2. Live Functional Test:​ Install in Series 90-30 test rack, power-on self-check, dual Ethernet handshake (ping test at 100 Mbps), simulate 2048 I/O load, run 24 hr test with temp logging (logged 0°C to 58°C range).
  3. Electrical Parameter Test:​ Megger insulation at 500 V (>10 MΩ), verify DC input draw (7.4 W nominal at 5 V), check ground continuity with Fluke 115.
  4. Firmware Verification:​ Read firmware version (record v6.2), photograph DIP switches (all off) and Ethernet configuration settings.
  5. Final QC & Packaging:​ Inspector signs off, seal in anti-static bag with desiccant, bubble wrap + double-walled carton, apply QC Passed label with date and Ethernet test results.
GE IC693CPU374

GE IC693CPU374

Replacement Pitfall Guide (Field Engineer’s Warnings)

Swapping this dual-Ethernet module introduces specific network risks. Keep these five points in mind and you’ll eliminate roughly 90% of rework.

  1. ❗ Dual Ethernet Port Configuration:​ Both ports share the same IP address but act as an internal switch. Misconfigured DLR topology causes network loops.​ Document existing network settings before removal .
  2. ❗ Firmware Rev Mismatch:​ New module firmware may lack DLR support present in older versions. Record current firmware before swapping. Case: Swapped V5.8 for V6.2—network showed “DLR Not Supported” until downgrade.
  3. ❗ Power Budget Shortfall:​ This unit draws 7.4 W—higher than non-Ethernet CPUs. Calculate total rack load, maintain 20% headroom. Added 8 AI modules? Rack hit 75 W; 24 V/3 A supply tripped.
  4. ❗ Ethernet PHY ESD Sensitivity:​ The dual Ethernet chips are static-sensitive. Wear a wrist strap. Work on an anti-static mat. A module powered up but showed “Link Down” on both ports—$3,500 loss from skipping ESD precautions.
  5. ❗ RS-485 Serial Port Access:​ Well, technically it supports SNP/SNPX via the power connector, not a dedicated serial port. Verify existing configuration before installation. Mismatched jumper settings caused Modbus RTU comms failure.