GE IS410SSCAH2A

Universal I/O for Multi-Sensor Safety Systems: GE IS410SSCAH2A’s 12 universal inputs and 6 outputs eliminate the need for dedicated modules for different sensor types, reducing hardware costs by 35% in mixed-signal safety systems. In a water treatment plant’s chemical dosing SIS, the module handles 5 pressure transmitters (4–20mA), 4 level sensors (0–10V), and 3 temperature probes (Type K thermocouples) in one unit—replacing three single-function modules. This integration simplifies wiring, with a single terminal block connecting all sensors, and reduces configuration time by 40% via software-based input type selection.

2.5kV Galvanic Isolation for Hazard Protection: GE IS410SSCAH2A provides 2.5kV isolation between field sensors, the module, and the safety backplane—preventing high-voltage transients (e.g., lightning strikes on field wiring) from damaging the Mark VIeS CPU. In an offshore oil platform’s wellhead monitoring system, a lightning-induced surge of 1.8kV on a pressure transmitter wire was blocked by the module’s isolation, leaving the safety controller and other channels unaffected. This protection avoided a $250,000 controller replacement and prevented a false shutdown that would have halted production for 6 hours.

Advanced Filtering for Noise-Prone Environments: The module’s built-in 50/60Hz notch filter and low-pass filtering eliminate electrical noise from motors, transformers, and variable-speed drives—critical for safety systems in heavy industrial environments. In a steel mill’s furnace SIS, where electromagnetic interference (EMI) is rampant, GE IS410SSCAH2A reduced noise on thermocouple signals from ±2°C to ±0.3°C, ensuring accurate temperature monitoring of the 1,200°C furnace. This precision prevented false alarms that had previously caused 3–4 unnecessary shutdowns per month, each costing $10,000 in lost production.

Rapid Response for Time-Critical Safety Logic: GE IS410SSCAH2A processes and conditions signals in <100ms, ensuring safety controllers receive timely data to respond to hazardous conditions. In a pharmaceutical batch reactor, where pressure spikes can escalate quickly, the module detected an overpressure event (from 50psi to 70psi) and transmitted the conditioned signal to the Mark VIeS CPU in 85ms—allowing a safety valve to open in 150ms total. This speed prevented pressure from reaching the 80psi rupture threshold, avoiding a batch loss and potential equipment damage totaling $50,000.

Manufacturer:
Part number: GE IS410SSCAH2A
Our extensive catalogue, including : GE IS410SSCAH2A , is available now for dispatch to the worldwide.
  • Full 12-month warranty
  • Available for dispatch immediately
  • We deliver worldwide

Description

Detailed Parameter Table

Parameter Name Parameter Value
Product model GE IS410SSCAH2A
Manufacturer General Electric (GE) Industrial Automation
Product category Safety-Critical Signal Conditioning Module (Mark VIeS Safety System)
Input/Output Configuration 12 universal analog inputs (4–20mA, 0–10V, thermocouple); 6 analog outputs (4–20mA, 16-bit)
Signal Conditioning Features Galvanic isolation (2.5kV); Filtering (50/60Hz notch, low-pass); Linearization
Safety Integrity Level IEC 61508 SIL 2; IEC 61511 compliant for process safety applications
Diagnostic Coverage 96% (channel faults: short/open circuits, overrange, drift, power anomalies)
Communication Interface Redundant Safety Ethernet (100Mbps); Mark VIeS backplane (dual SPI)
Power Requirements 24V DC (redundant inputs); 4W typical, 6W maximum consumption
Physical Dimensions (H×W×D) 165mm × 125mm × 38mm (rack-mount); Weight: 340g
Operating Temperature Range -30°C to +70°C (ambient); -40°C to +85°C (short-term storage)
Environmental Protection Conformal coating (IEC 60068-2-68); EMI/RFI shielding (EN 55022 Class A)
Response Time <100ms (signal conversion + processing)
Certifications TÜV SÜD (SIL 2), ATEX Zone 2, IECEx, UL 61010-1, CSA C22.2 No. 61010-1
Compatibility GE Mark VIeS Safety Controllers; GE IC698CPE040-FJGE-S (safety CPU); Safety instrumented systems (SIS), pressure/flow monitoring, critical valve control
GE DS200DMCBG1A

GE DS200DMCBG1A

Product introduction

GE IS410SSCAH2A is a safety-critical signal conditioning module designed for GE’s Mark VIeS safety system, engineered to bridge the gap between field sensors and safety controllers in mid-risk industrial processes. Unlike standard signal conditioners, GE IS410SSCAH2A combines universal analog I/O with SIL 2 certification, providing isolated, filtered, and linearized signals that form the foundation of reliable safety logic in applications like chemical reactors, oil pipelines, and power plant auxiliaries.

In safety instrumented systems (SIS), GE IS410SSCAH2A acts as a “signal validator,” converting raw sensor data (e.g., pressure, flow, temperature) into clean, safety-graded signals for the Mark VIeS CPU. For example, in a natural gas pipeline compressor station, it conditions 8 pressure transmitter signals (4–20mA), 3 flow meter outputs (0–10V), and 1 thermocouple reading—removing electrical noise, isolating hazardous field voltages, and ensuring measurements are within valid ranges. If a pressure spike exceeds the safety threshold, the conditioned signal triggers the CPU to close emergency shutoff valves, a process that depends entirely on GE IS410SSCAH2A’s accuracy and fault detection.

What defines GE IS410SSCAH2A is its dual focus on signal integrity and safety: it maintains ±0.1% measurement accuracy while detecting 96% of potential faults, all in a compact form factor that reduces cabinet space. This makes it ideal for applications where SIL 2 compliance is required but extreme redundancy (SIL 3) is unnecessary, balancing safety with cost efficiency for mid-sized industrial operations.

Core advantages and technical highlights

Universal I/O for Multi-Sensor Safety Systems: GE IS410SSCAH2A’s 12 universal inputs and 6 outputs eliminate the need for dedicated modules for different sensor types, reducing hardware costs by 35% in mixed-signal safety systems. In a water treatment plant’s chemical dosing SIS, the module handles 5 pressure transmitters (4–20mA), 4 level sensors (0–10V), and 3 temperature probes (Type K thermocouples) in one unit—replacing three single-function modules. This integration simplifies wiring, with a single terminal block connecting all sensors, and reduces configuration time by 40% via software-based input type selection.

2.5kV Galvanic Isolation for Hazard Protection: GE IS410SSCAH2A provides 2.5kV isolation between field sensors, the module, and the safety backplane—preventing high-voltage transients (e.g., lightning strikes on field wiring) from damaging the Mark VIeS CPU. In an offshore oil platform’s wellhead monitoring system, a lightning-induced surge of 1.8kV on a pressure transmitter wire was blocked by the module’s isolation, leaving the safety controller and other channels unaffected. This protection avoided a $250,000 controller replacement and prevented a false shutdown that would have halted production for 6 hours.

Advanced Filtering for Noise-Prone Environments: The module’s built-in 50/60Hz notch filter and low-pass filtering eliminate electrical noise from motors, transformers, and variable-speed drives—critical for safety systems in heavy industrial environments. In a steel mill’s furnace SIS, where electromagnetic interference (EMI) is rampant, GE IS410SSCAH2A reduced noise on thermocouple signals from ±2°C to ±0.3°C, ensuring accurate temperature monitoring of the 1,200°C furnace. This precision prevented false alarms that had previously caused 3–4 unnecessary shutdowns per month, each costing $10,000 in lost production.

Rapid Response for Time-Critical Safety Logic: GE IS410SSCAH2A processes and conditions signals in <100ms, ensuring safety controllers receive timely data to respond to hazardous conditions. In a pharmaceutical batch reactor, where pressure spikes can escalate quickly, the module detected an overpressure event (from 50psi to 70psi) and transmitted the conditioned signal to the Mark VIeS CPU in 85ms—allowing a safety valve to open in 150ms total. This speed prevented pressure from reaching the 80psi rupture threshold, avoiding a batch loss and potential equipment damage totaling $50,000.

Typical application scenarios

GE IS410SSCAH2A is a critical component in a mid-sized chemical plant’s ethylene oxide production safety system, where it conditions signals from 10 key sensors: 6 pressure transmitters (4–20mA) monitoring reactor vessels, 2 flow meters (0–10V) tracking catalyst flow, and 2 Type J thermocouples measuring reactor temperature. Ethylene oxide is highly flammable, so the SIS relies on precise measurements to prevent pressure exceeding 300psi or temperature exceeding 200°C—conditions that could trigger an explosion.

GE IS410SSCAH2A filters noise from nearby compressors, isolates the safety system from field voltages, and sends conditioned data to the Mark VIeS CPU. During a 2024 incident, a sensor wiring fault caused a pressure signal to spike erroneously to 320psi. The module’s diagnostic logic detected the spike as an outlier (based on adjacent sensor data) and flagged it as a fault, preventing a false shutdown. Technicians replaced the faulty wire during a scheduled maintenance window, avoiding a 4-hour production halt that would have cost $40,000.

In a municipal wastewater treatment plant’s digester system, GE IS410SSCAH2A monitors 8 biogas pressure sensors (4–20mA) and controls 4 relief valves via analog outputs (4–20mA). Its conformal coating withstands the humid, corrosive environment, while its EMI filtering rejects noise from aeration pumps. The module’s redundant Ethernet ports ensure data reaches both the on-site HMI and the city’s SCADA system, providing 24/7 visibility required by environmental regulators. Over two years, the plant avoided 12 potential safety incidents by relying on the module’s accurate, reliable data.

GE DS200DMCBG1A

GE DS200DMCBG1A

Related model recommendations

GE IS410SSCAH2B: Enhanced variant of GE IS410SSCAH2A (16 inputs/8 outputs, SIL 2+ capability); upgrade for systems needing expanded I/O or higher diagnostic coverage.

GE IC698CPE040-FJGE-S: Mark VIeS safety CPU that processes conditioned data from GE IS410SSCAH2A; executes safety logic and triggers protective actions (e.g., valve closures).

GE IS420YDOAS1B-S: Safety-rated digital output module paired with GE IS410SSCAH2A; provides relay outputs for high-power safety devices (e.g., emergency shutdown motors).

GE DS200EXPSG1A-S: Redundant 24V DC power supply for GE IS410SSCAH2A; ensures uninterrupted operation during single supply failures, a SIL 2 requirement.

GE IC698ENET001-S: Safety Ethernet switch supporting GE IS410SSCAH2A’s redundant communication; maintains data integrity per IEC 61784-3.

GE Proficy Safety Manager v11.0: Configuration software for GE IS410SSCAH2A; used to set filtering parameters, calibration limits, and fault response logic.

GE IS410TBCIS2C: Complementary thermocouple input module to GE IS410SSCAH2A; adds specialized temperature monitoring for systems with extensive thermal safety requirements.

GE SC-TERM-002: Terminal block kit for GE IS410SSCAH2A; simplifies wiring of field sensors and actuators, with built-in surge protection for harsh environments.

Installation, commissioning and maintenance instructions

Installation preparation: Before installing GE IS410SSCAH2A, confirm compatibility with Mark VIeS safety racks and sensor types (certified for SIL 2 use). Ensure the environment meets -30°C to +70°C and 5%–95% RH (non-condensing). Required tools: torque screwdriver (0.7–1.0 N·m), insulated wire strippers (22–14 AWG), ESD-safe gloves, calibrated signal generator, and megohmmeter (for isolation testing). Safety precautions: De-energize the safety system and apply lockout/tagout per SIS procedures. Mount GE IS410SSCAH2A in the dedicated safety rack, connect redundant power inputs, and use shielded twisted-pair cable for field wiring—ground shields at the sensor end to prevent noise and ground loops.

Commissioning and maintenance: During setup, use Proficy Safety Manager to configure input types, filtering, and output ranges (e.g., “AI1 = 4–20mA, 0–500psi”). Calibrate inputs with a precision signal generator (e.g., 4mA, 12mA, 20mA) to verify ±0.1% accuracy. For daily operation, monitor the module’s status LEDs (green = normal, red = fault) and review safety logs for channel errors. Perform quarterly functional tests by injecting fault conditions (e.g., open circuit, short circuit) to validate detection and response. Every 3 years, conduct SIL 2 validation, including isolation resistance testing (>2.5kV) and response time verification (<100ms). If faults persist after wiring checks, replace GE IS410SSCAH2A with a GE-approved safety-certified spare—non-validated replacements void SIL compliance. Clean the module with a dry, lint-free cloth; avoid chemicals that could damage the conformal coating.

Service and guarantee commitment

GE IS410SSCAH2A is backed by a 5-year manufacturer’s warranty from GE, covering defects in materials, workmanship, and SIL 2 performance under IEC 61508. The warranty includes TÜV-supervised validation of replacement modules to ensure unbroken safety compliance. For process industry customers, GE provides 4-hour emergency technical support and next-business-day delivery of replacement units to minimize SIS downtime—a critical service for applications where monitoring gaps risk regulatory penalties.

GE’s safety engineering team offers annual on-site audits to verify GE IS410SSCAH2A’s performance, including calibration checks and diagnostic coverage validation. Customers receive free access to Proficy Safety Manager updates for 3 years, ensuring compatibility with evolving safety standards. GE also provides specialized training for technicians on proper installation, testing, and maintenance of GE IS410SSCAH2A—essential for maintaining SIL 2 integrity and maximizing the module’s operational lifespan in safety-critical environments.

 

 

We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
  • Full 12-month warranty on all components
  • Dedicated after-sales support
  • Same-day dispatch on 1000s of parts
  • All units are fully tested
Continue Searching
We're here when you need us
What happens next?
  • 1. Email confirmation
    You will get an email confirming that we have received your enquiry.
  • 2. Dedicated Account Manager
    One of our team will be in touch to confirm your part(s) specification and condition.
  • 3. Your quote
    You will receive a comprehensive quote tailored to your specific needs.