IS200SCTTG1A

Multi-Protocol Support for Flexible Integration: The IS200SCTTG1A stands out by supporting both Modbus RTU (RS-485) and Modbus TCP/IP—eliminating the need for separate communication modules for serial and Ethernet devices. This flexibility allows it to connect to a wide range of equipment: legacy devices (e.g., old pressure gauges with RS-485 ports) and modern smart devices (e.g., IoT-enabled temperature sensors with Ethernet) can both communicate with the Ovation DCS via a single IS200SCTTG1A module. This reduces hardware costs by up to 40% compared to using dedicated serial and Ethernet modules.

Isolated & Surge-Protected Ports for Reliability: Unlike many communication modules with non-isolated ports, the IS200SCTTG1A features fully isolated RS-485 ports (15 kV ESD protection) and overcurrent-protected Ethernet ports. This isolation prevents ground loops—common in industrial settings where devices are powered by different electrical systems—from causing communication errors or module damage. For example, in a chemical plant with multiple VFDs (which generate electrical noise), the IS200SCTTG1A’s surge protection ensures uninterrupted data transmission from nearby flow sensors, avoiding costly process disruptions.

High Scalability for Growing Systems: The IS200SCTTG1A supports up to 32 devices per RS-485 port (via daisy-chain) and unlimited devices via Ethernet—making it suitable for both small-scale and large-scale systems. In a municipal water treatment plant, for instance, a single IS200SCTTG1A can connect to 32 pressure sensors across multiple pump stations (via RS-485) and 50 smart water meters (via Ethernet), eliminating the need to add additional communication modules as the plant expands. The module’s auto-negotiating Ethernet port (10/100 Mbps) also adapts to existing network infrastructure, reducing upgrade costs.

Built-In Diagnostics for Proactive Maintenance: The IS200SCTTG1A includes comprehensive diagnostic features that monitor port status, protocol errors, and power supply health. If a Modbus RTU device drops off the network (e.g., due to a broken RS-485 wire), the module logs the error and sends an alert to the Ovation HMI—enabling operators to identify and resolve issues before they affect production. It also tracks communication latency and packet loss for Ethernet connections, helping technicians optimize network performance. These diagnostics reduce unplanned downtime by up to 30% compared to modules with basic or no diagnostic capabilities.

Seamless Ovation Platform Integration: The IS200SCTTG1A is designed to work natively with the Ovation DCS, requiring no custom drivers or programming. Engineers can configure the module’s ports, protocols, and data mapping directly via Emerson’s Ovation Control Studio software—same tool used to program the Ovation controller. This streamlines commissioning time by 25%: instead of learning a new configuration tool, teams can set up the IS200SCTTG1A using familiar software, reducing training costs and human error.

Manufacturer:
Part number: IS200SCTTG1A
Our extensive catalogue, including : IS200SCTTG1A , is available now for dispatch to the worldwide.
  • Full 12-month warranty
  • Available for dispatch immediately
  • We deliver worldwide

Description

Detailed Parameter Table

Parameter Name Parameter Value
Product model IS200SCTTG1A
Manufacturer Emerson Automation Solutions (Ovation DCS Division)
Product category Industrial Communication Interface Module (for Ovation DCS)
Supported communication protocols Modbus RTU (RS-485); Modbus TCP/IP; Ovation Control Network (OCN)
Communication ports 2 x RS-485 serial ports (isolated); 1 x 10/100 Base-T Ethernet port (RJ45)
Data transfer rate RS-485: 1200 bps – 115.2 kbps (configurable); Ethernet: 10/100 Mbps (auto-negotiation)
Serial port parity options None, Even, Odd, Mark, Space
Maximum connected devices RS-485: Up to 32 devices per port (via daisy-chain); Ethernet: Unlimited (via TCP/IP network)
Operating temperature range 0 °C to 60 °C (32 °F to 140 °F); -40 °C to 70 °C (storage)
Physical dimensions 165 mm (W) × 102 mm (H) × 229 mm (D) (6.50 in × 4.02 in × 9.02 in)
Installation method Ovation 3U I/O chassis mounting (compatible with IS200-series I/O racks)
Power supply requirements 5 V DC (±5%); 1.2 A maximum current draw; Powered via Ovation chassis backplane
Protection features RS-485 port surge protection (15 kV ESD); Ethernet port overcurrent protection; Backplane power isolation
Safety & EMC compliance IEC 61010-1 (CAT III, 600 V); EN 61326-1 (EMC immunity: Level 3); UL 61010-1
MTBF (Mean Time Between Failures) 2,000,000 hours (per Telcordia SR-332, at 40 °C ambient)
Diagnostic capabilities Port communication status monitoring; Protocol error logging; Power supply fault detection
Weight 450 g (0.99 lb)
IS200EMIOH1A

IS200EMIOH1A

Product Introduction

The IS200SCTTG1A is a versatile communication interface module from Emerson’s Ovation distributed control system (DCS) portfolio, designed to serve as the “data bridge” between Ovation controllers and external industrial devices. As a core connectivity component of the Ovation platform, the IS200SCTTG1A supports both Modbus RTU (RS-485) and Modbus TCP/IP protocols—two of the most widely used industrial communication standards—enabling seamless integration with third-party sensors, meters, drives, and even legacy control systems.

This module eliminates communication silos in automation systems by translating data between the Ovation Control Network (OCN) and external devices. For example, it can collect real-time flow rate data from a third-party ultrasonic flowmeter (via Modbus RTU) and transmit it to the Ovation controller, or send control commands from the Ovation HMI to a variable frequency drive (VFD) via Modbus TCP/IP. The IS200SCTTG1A’s isolated serial ports and surge protection ensure stable communication even in electrically noisy industrial environments, making it indispensable for industries like power generation, chemical processing, and water treatment where integrated data exchange is critical for operational efficiency.

Core Advantages and Technical Highlights

Multi-Protocol Support for Flexible Integration: The IS200SCTTG1A stands out by supporting both Modbus RTU (RS-485) and Modbus TCP/IP—eliminating the need for separate communication modules for serial and Ethernet devices. This flexibility allows it to connect to a wide range of equipment: legacy devices (e.g., old pressure gauges with RS-485 ports) and modern smart devices (e.g., IoT-enabled temperature sensors with Ethernet) can both communicate with the Ovation DCS via a single IS200SCTTG1A module. This reduces hardware costs by up to 40% compared to using dedicated serial and Ethernet modules.

Isolated & Surge-Protected Ports for Reliability: Unlike many communication modules with non-isolated ports, the IS200SCTTG1A features fully isolated RS-485 ports (15 kV ESD protection) and overcurrent-protected Ethernet ports. This isolation prevents ground loops—common in industrial settings where devices are powered by different electrical systems—from causing communication errors or module damage. For example, in a chemical plant with multiple VFDs (which generate electrical noise), the IS200SCTTG1A’s surge protection ensures uninterrupted data transmission from nearby flow sensors, avoiding costly process disruptions.

High Scalability for Growing Systems: The IS200SCTTG1A supports up to 32 devices per RS-485 port (via daisy-chain) and unlimited devices via Ethernet—making it suitable for both small-scale and large-scale systems. In a municipal water treatment plant, for instance, a single IS200SCTTG1A can connect to 32 pressure sensors across multiple pump stations (via RS-485) and 50 smart water meters (via Ethernet), eliminating the need to add additional communication modules as the plant expands. The module’s auto-negotiating Ethernet port (10/100 Mbps) also adapts to existing network infrastructure, reducing upgrade costs.

Built-In Diagnostics for Proactive Maintenance: The IS200SCTTG1A includes comprehensive diagnostic features that monitor port status, protocol errors, and power supply health. If a Modbus RTU device drops off the network (e.g., due to a broken RS-485 wire), the module logs the error and sends an alert to the Ovation HMI—enabling operators to identify and resolve issues before they affect production. It also tracks communication latency and packet loss for Ethernet connections, helping technicians optimize network performance. These diagnostics reduce unplanned downtime by up to 30% compared to modules with basic or no diagnostic capabilities.

Seamless Ovation Platform Integration: The IS200SCTTG1A is designed to work natively with the Ovation DCS, requiring no custom drivers or programming. Engineers can configure the module’s ports, protocols, and data mapping directly via Emerson’s Ovation Control Studio software—same tool used to program the Ovation controller. This streamlines commissioning time by 25%: instead of learning a new configuration tool, teams can set up the IS200SCTTG1A using familiar software, reducing training costs and human error.

Typical Application Scenarios

In combined-cycle power plants, the IS200SCTTG1A plays a key role in integrating auxiliary systems with the Ovation DCS. It connects to third-party equipment like boiler feedwater pumps (via Modbus RTU, RS-485) to collect motor current and temperature data, and to smart energy meters (via Modbus TCP/IP) to track fuel consumption. This integrated data allows the Ovation controller to optimize boiler efficiency—for example, adjusting feedwater flow based on real-time pump current data—reducing fuel costs by up to 5% annually. The IS200SCTTG1A’s surge protection also ensures reliable communication during power grid fluctuations, critical for maintaining stable turbine operation.

Chemical processing facilities use the IS200SCTTG1A to integrate legacy batch controllers with the Ovation DCS. Many older batch reactors use Modbus RTU-enabled controllers that cannot communicate directly with modern DCS platforms, but the IS200SCTTG1A translates their data into a format the Ovation controller can understand. For example, it collects batch temperature and pressure data from a legacy controller (via RS-485) and sends it to the Ovation HMI, allowing operators to monitor batch progress alongside data from newer Ovation-compatible sensors. This integration avoids the need to replace expensive legacy equipment, saving up to 60% on upgrade costs.

Municipal wastewater treatment plants rely on the IS200SCTTG1A to connect distributed sensor networks to the Ovation DCS. It uses Modbus RTU (RS-485) to collect data from level sensors in remote lift stations (up to 1 km away, via daisy-chain) and Modbus TCP/IP to send control commands to valve actuators at the main treatment facility. The module’s scalability allows the plant to add more sensors as it expands service areas, while its diagnostics alert operators to sensor failures (e.g., a broken level sensor wire) before they cause overflow incidents—complying with environmental regulations and avoiding fines.

IS200EMIOH1A

IS200EMIOH1A

Related Model Recommendations

IS200ENETIH1A: A dedicated Ethernet communication module from Emerson that complements the IS200SCTTG1A by adding additional Ethernet ports (4 x 10/100 Base-T) for large-scale Modbus TCP/IP deployments (e.g., connecting 100+ smart meters).

IS200SDIIH1A: Emerson’s high-density digital input module that pairs with the IS200SCTTG1A—the IS200SCTTG1A collects data from third-party devices, while the IS200SDIIH1A collects discrete signals from Ovation-compatible sensors, forming a complete input system.

1C31234G01: Ovation’s main controller that communicates directly with the IS200SCTTG1A—the module sends external device data to the controller, which executes control logic based on integrated data from both Ovation and third-party devices.

IS200SRTTG1A: A serial-only communication module (Modbus RTU, RS-485) that serves as a cost-effective alternative to the IS200SCTTG1A for systems with no Ethernet devices (e.g., legacy factories with only RS-485-enabled equipment).

IS200SHRAH2A: Emerson’s analog I/O module that works with the IS200SCTTG1A—the IS200SCTTG1A collects digital data from third-party meters, while the IS200SHRAH2A collects analog data (e.g., pressure, flow) from Ovation-compatible sensors.

IS200VCRLY1A: A relay output module that integrates with the IS200SCTTG1A—the module receives control commands from the Ovation controller (via OCN) and sends them to third-party relays (via Modbus), enabling control of high-power devices like pumps.

Emerson Rosemount 8732E: A third-party ultrasonic flowmeter that pairs with the IS200SCTTG1A—the flowmeter sends real-time flow data to the module via Modbus RTU, which transmits it to the Ovation DCS for process monitoring.

Schneider Electric ATV340 VFD: A VFD that communicates with the IS200SCTTG1A via Modbus TCP/IP—the Ovation HMI sends speed adjustment commands to the VFD through the module, optimizing motor performance in applications like conveyor systems.

Installation, Commissioning and Maintenance Instructions

Installation preparation: Before installing the IS200SCTTG1A, ensure the Ovation 3U I/O chassis is powered off and grounded per Emerson’s guidelines (minimum 4 mm² ground wire). Verify the chassis slot is compatible with IS200-series modules and the environment meets the module’s operating temperature (0-60 °C) and humidity (10-90%, non-condensing) requirements. Required tools include a torque screwdriver (for module mounting, torque setting: 0.5-0.8 N·m), wire strippers (for RS-485 wiring: 22-18 AWG twisted-pair cable), and a network cable tester (for Ethernet port verification). For RS-485 wiring, use shielded twisted-pair cable (ground the shield at one end only) to minimize noise; for Ethernet, use Cat5e or higher cable (maximum length: 100 m). Always disconnect power to the I/O chassis before inserting the IS200SCTTG1A to prevent backplane damage.

Maintenance suggestions: For daily maintenance of the IS200SCTTG1A, check the module’s LED status lights (power: green, RS-485 communication: amber, Ethernet communication: green, fault: red) during shift handovers—red LEDs indicate critical issues (e.g., power failure), while flashing amber/green LEDs signal communication errors. Every 3 months, clean the module’s vents with compressed air (max 40 psi) to remove dust and inspect RS-485/Ethernet connections for tightness (re-torque terminal screws to 0.3 N·m if loose). Use Ovation Control Studio to run monthly diagnostic tests: check for protocol errors, packet loss, and device connection status. If a communication fault occurs (e.g., a Modbus device is unreachable), first test the wiring with a multimeter (for RS-485) or network tester (for Ethernet) before replacing the IS200SCTTG1A. Use only Emerson-approved spare modules to ensure compatibility with the Ovation DCS.

Service and Guarantee Commitment

The IS200SCTTG1A comes with a 2-year standard warranty from Emerson Automation Solutions, covering defects in materials, workmanship, and performance under normal industrial use. If the module fails within this period (e.g., port malfunction, communication dropout), Emerson will repair or replace it free of charge, with expedited shipping (24-48 hours for regional warehouses) to minimize operational downtime—critical for systems where communication failures can disrupt data collection or control.

Emerson offers 24/7 global technical support for the IS200SCTTG1A: certified Ovation engineers specialize in communication integration and can assist with port configuration, protocol troubleshooting, and third-party device compatibility via phone, email, or remote access (through Emerson’s Remote Support Portal). Customers gain access to the Emerson Ovation Knowledge Base, which includes the IS200SCTTG1A’s technical manual, wiring diagrams, firmware updates, and application notes (e.g., “Integrating Modbus RTU Devices with Ovation DCS”).

For mission-critical applications (e.g., nuclear power plant auxiliary systems), Emerson provides extended warranty options (up to 5 years) and annual preventive maintenance services—trained technicians perform on-site port testing, firmware upgrades, and communication latency checks to proactively address potential issues. This commitment reflects Emerson’s confidence in the IS200SCTTG1A’s reliability and its dedication to helping customers maintain seamless data exchange in their automation systems.

 

We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
  • Full 12-month warranty on all components
  • Dedicated after-sales support
  • Same-day dispatch on 1000s of parts
  • All units are fully tested
Continue Searching
We're here when you need us
What happens next?
  • 1. Email confirmation
    You will get an email confirming that we have received your enquiry.
  • 2. Dedicated Account Manager
    One of our team will be in touch to confirm your part(s) specification and condition.
  • 3. Your quote
    You will receive a comprehensive quote tailored to your specific needs.