IS200STAIH2A

Multi-Sensor Support: The IS200STAIH2A can be configured to accept various input types on a per-channel basis, eliminating the need for separate modules for different sensor technologies. This flexibility reduces system complexity and hardware costs.

Exceptional Measurement Accuracy: With 16-bit resolution and ±0.05% accuracy, the IS200STAIH2A provides precise measurements that are essential for turbine control applications where small parameter changes can significantly impact performance and safety.

Advanced Signal Conditioning: The module incorporates sophisticated signal conditioning circuitry that minimizes noise and drift, ensuring stable measurements even in the electrically noisy environment of a power plant.

High Isolation Levels: The IS200STAIH2A features 2.5kV channel-to-channel isolation and 5kV field-to-backplane isolation, protecting sensitive control electronics from high-voltage transients and ensuring safe operation.

Robust Industrial Design: Built to withstand harsh industrial environments, the IS200STAIH2A operates reliably across a wide temperature range (-40°C to +85°C) and is resistant to vibration and electromagnetic interference.

Manufacturer:
Part number: IS200STAIH2A
Our extensive catalogue, including : IS200STAIH2A , is available now for dispatch to the worldwide.
  • Full 12-month warranty
  • Available for dispatch immediately
  • We deliver worldwide

Description

Professional Product Description: GE IS200STAIH2A

Detailed Parameter Table

Parameter Name Parameter Value
Product model IS200STAIH2A
Manufacturer General Electric (GE)
Product category Steam Turbine Analog Input Module (Mark VIe Speedtronic)
Core function Analog signal acquisition, conditioning, and processing for turbine control
Input channels 16 analog inputs (16-bit resolution)
Input types supported 4-20 mA, 0-10V DC, thermocouples (J, K, T, E, R, S, B), RTDs (Pt100, Ni100)
Isolation Channel-to-channel: 2.5kV RMS; Field-to-backplane: 5kV RMS
Sampling rate 100 samples per second per channel
Accuracy ±0.05% of full scale (at 25°C)
Operating temperature -40°C to +85°C
Power requirements 24VDC (±10%); 0.4A max
Communication interface Mark VIe backplane
Safety compliance IEC 61010-1; EN 61326-1; UL 61010-1
MTBF 3,200,000 hours (at 40°C)
IS200EGPAG1A

IS200EGPAG1A

Product Introduction

The IS200STAIH2A is a high-performance analog input module designed by GE specifically for steam turbine control applications within the Mark VIe Speedtronic system. This module serves as the critical interface between the turbine’s analog sensors and the main control system, providing precise signal conditioning and processing.

With 16 configurable analog input channels, the IS200STAIH2A can accommodate various sensor types including 4-20 mA current loops, 0-10V voltage signals, thermocouples, and RTDs. This versatility makes it ideal for monitoring diverse turbine parameters such as temperatures, pressures, flow rates, and valve positions.

The IS200STAIH2A plays a vital role in turbine control and protection by providing accurate, reliable measurements to the main controller. Its high-resolution conversion (16-bit), exceptional accuracy (±0.05%), and fast sampling rate (100 S/s) ensure that critical turbine data is captured and processed with minimal delay, enabling precise control and rapid response to changing conditions.

Core Advantages and Technical Highlights

Multi-Sensor Support: The IS200STAIH2A can be configured to accept various input types on a per-channel basis, eliminating the need for separate modules for different sensor technologies. This flexibility reduces system complexity and hardware costs.

Exceptional Measurement Accuracy: With 16-bit resolution and ±0.05% accuracy, the IS200STAIH2A provides precise measurements that are essential for turbine control applications where small parameter changes can significantly impact performance and safety.

Advanced Signal Conditioning: The module incorporates sophisticated signal conditioning circuitry that minimizes noise and drift, ensuring stable measurements even in the electrically noisy environment of a power plant.

High Isolation Levels: The IS200STAIH2A features 2.5kV channel-to-channel isolation and 5kV field-to-backplane isolation, protecting sensitive control electronics from high-voltage transients and ensuring safe operation.

Robust Industrial Design: Built to withstand harsh industrial environments, the IS200STAIH2A operates reliably across a wide temperature range (-40°C to +85°C) and is resistant to vibration and electromagnetic interference.

Typical Application Scenarios

In coal-fired power plants, the IS200STAIH2A is used to monitor critical steam turbine parameters such as bearing temperatures, steam pressures, and valve positions. These measurements are essential for the Mark VIe controller to maintain optimal turbine performance and prevent equipment damage.

For example, during turbine startup, the IS200STAIH2A provides precise temperature measurements from RTD sensors embedded in the turbine bearings. The control system uses this data to ensure proper warm-up sequences are followed, preventing thermal stress on turbine components.

In combined-cycle power plants, the IS200STAIH2A monitors steam conditions from the heat recovery steam generator (HRSG) and provides this information to the control system for optimal steam turbine operation. It also measures fuel flow rates and other parameters essential for efficient plant operation.

The IS200STAIH2A is also crucial for turbine protection systems, providing the accurate measurements needed to detect abnormal conditions such as excessive vibration, bearing temperature excursions, or steam pressure anomalies that could lead to equipment failure.

Related Model Recommendations

IS200STAO1A – Steam turbine analog output module that works with the IS200STAIH2A to provide control signals to actuators and valves.

IS200DTAIH1A – Digital input module that complements the IS200STAIH2A for monitoring discrete turbine status signals.

IS200DTACH1A – Digital output module that pairs with the IS200STAIH2A for controlling discrete devices in the turbine system.

IS200STTCH2A – Steam turbine trip control module that uses data from the IS200STAIH2A for turbine protection functions.

IS200STURH1A – Turbine speed control module that relies on accurate measurements from the IS200STAIH2A for precise speed regulation.

IS200EACFG2A – Configuration module that stores the IS200STAIH2A’s calibration data and configuration parameters.

IS200EHBQG2A – Backplane module that provides power and communication connectivity for the IS200STAIH2A.

IS200JGNDG1A – Grounding module that enhances signal integrity for the IS200STAIH2A by reducing noise and preventing ground loops.

IS200EGPAG1A

Installation, Commissioning and Maintenance Instructions

Installation preparation: Before installing the IS200STAIH2A, ensure the Mark VIe backplane is powered down. Verify that the operating environment meets the module’s specifications (-40°C to +85°C). Use ESD-protective equipment during handling. Confirm that the backplane slot is compatible with analog input modules and that the 24VDC power supply meets the required specifications (±10% tolerance).

For sensor wiring, use shielded twisted-pair cables appropriate for the signal type. Follow GE’s wiring guidelines for proper grounding and signal routing to minimize noise interference. Each channel should be clearly labeled to facilitate troubleshooting and maintenance.

Commissioning: After physical installation, configure the IS200STAIH2A using GE’s ToolboxST software. Set each channel’s input type, scaling, and alarm thresholds according to the specific application requirements. Perform calibration using appropriate standards to ensure measurement accuracy.

Verify communication with the main controller and perform functional tests to ensure all channels are operating correctly. Document the configuration for future reference and maintenance.

Maintenance suggestions: Regularly monitor the IS200STAIH2A status through the Mark VIe HMI. Review diagnostic information to identify any potential issues with the module or connected sensors. Perform periodic calibration to maintain measurement accuracy, especially after major maintenance or component replacement.

Inspect wiring connections periodically for tightness and corrosion. Keep firmware updated to the latest version recommended by GE. If a failure occurs, follow proper lockout/tagout procedures before replacement. Always use GE-approved replacement parts to ensure system compatibility and reliability.

Service and Guarantee Commitment

The IS200STAIH2A comes with a 2-year standard warranty from GE, covering defects in materials and workmanship. GE’s global service network provides comprehensive support for the IS200STAIH2A, including technical assistance, repair services, and spare parts availability.

GE offers 24/7 technical support for the IS200STAIH2A, with specialists available to assist with installation, configuration, and troubleshooting. Customers have access to GE’s extensive library of technical documentation, including user manuals, application notes, and best practices guides for analog measurement in turbine control systems.

For mission-critical applications, GE provides extended warranty options and preventive maintenance services to ensure the IS200STAIH2A operates at peak performance throughout its service life. GE’s commitment to quality ensures that the IS200STAIH2A will provide reliable measurement performance in even the most demanding power generation environments.

We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
  • Full 12-month warranty on all components
  • Dedicated after-sales support
  • Same-day dispatch on 1000s of parts
  • All units are fully tested
Continue Searching
We're here when you need us
What happens next?
  • 1. Email confirmation
    You will get an email confirming that we have received your enquiry.
  • 2. Dedicated Account Manager
    One of our team will be in touch to confirm your part(s) specification and condition.
  • 3. Your quote
    You will receive a comprehensive quote tailored to your specific needs.