Honeywell FC-QPP-0001 | Safety Manager Quad Processor Pack – SIL3 Certified & Redundant Control

  • Manufacturer: Honeywell
  • Part Number: FC-QPP-0001
  • System Platform: Honeywell Safety Manager (Second-Generation Safety Platform)
  • Hardware Type: Quad Processor Pack (QPP) – Core Control Module
  • Architectural Role: Executes SIL3 safety logic, manages I/O communication, and provides redundant processing for critical safety functions (e.g., emergency shutdown, fire & gas detection).
  • Key Specifications:
    • Processor: 4x PowerPC cores (quad modular redundant, QMR architecture)
    • Certification: SIL3 (IEC 61508)
    • Operating Temperature: -40°C to +70°C (Safety Manager Cabinet)
    • Communication: Ethernet, Modbus, Profibus (via integrated communication modules)
    • Redundancy: 2oo4D (two-out-of-four) voting logic for fault tolerance
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.

Description

System Architecture & Operational Principle

The Honeywell FC-QPP-0001 is the core processing unit​ of the Honeywell Safety Manager system, designed to deliver fail-safe control​ for industrial safety applications (e.g., chemical plants, oil & gas refineries, power generation). It operates within the Safety Manager architecture, which combines a rack-based controller with remote I/O capabilities to monitor and control critical process parameters.

Core Functional Blocks

The FC-QPP-0001 consists of three primary functional blocks, each optimized for safety and reliability:
  1. Quad Processor Array:
    • Four independent PowerPC processors execute safety logic in parallel, using 2oo4D voting logic​ to ensure that a single processor failure does not compromise system operation.
    • Each processor runs a copy of the safety application, and the results are compared in real time. If one processor deviates, the others override it, maintaining system integrity.
  2. I/O Management:
    • Interfaces with Universal Safety I/O (USIO)​ modules to collect data from field devices (e.g., pressure transmitters, temperature sensors, emergency stop buttons) and send control signals to actuators (e.g., valves, motor starters).
    • Supports multiple communication protocols (Ethernet, Modbus, Profibus) for seamless integration with existing plant networks.
  3. Diagnostics & Voting Logic:
    • Continuous self-diagnostics monitor processor health, memory integrity, and communication links. Faults (e.g., processor hang, memory corruption) trigger immediate alerts and switchover to redundant components.
    • The voting logic ensures that only valid, consensus-based outputs are sent to field devices, preventing spurious trips or unsafe states.

Operational Workflow

  1. Data Acquisition: The FC-QPP-0001 receives analog/digital signals from field devices via USIO modules.
  2. Logic Execution: The quad processors execute the safety application (e.g., “shut down turbine if pressure exceeds 100 bar”) in parallel.
  3. Voting & Output: The voting logic compares the four processor outputs. If three or more agree, the output is sent to the actuator. If not, a fault is logged, and the system switches to a safe state.
  4. Diagnostics: Continuous monitoring of processors, I/O, and communication links ensures early fault detection and minimizes downtime.

Core Technical Specifications

Parameter
Specification
Processor
4x PowerPC cores (quad modular redundant, QMR)
Architecture
2oo4D (two-out-of-four) voting logic
Certification
SIL3 (IEC 61508) – suitable for safety-critical applications
Operating Temperature
-40°C to +70°C (Safety Manager Cabinet); -5°C to +70°C (Remote Cabinet)
Communication
Ethernet (10/100 Mbps), Modbus RTU/TCP, Profibus DP
I/O Capacity
Supports up to 128 USIO channels (analog/digital) per controller
Power Supply
24 VDC (redundant power modules required)
Dimensions
19-inch rack-mount (3U height)
Weight
~5 kg (11 lbs)
Compliance
ANSI/ISA 7, IEC 61508, ISO 13849
HONEYWELL FC-QPP-0001

HONEYWELL FC-QPP-0001

Customer Value & Operational Benefits

1. SIL3 Certified Fail-Safe Control

The FC-QPP-0001’s QMR architecture and 2oo4D voting logic ensure fault-tolerant operation​ for safety-critical functions. This is essential for industries like chemical processing, where a single safety breach can result in catastrophic consequences (e.g., explosions, toxic releases).

2. Reduced Downtime with Redundancy

The quad processor design eliminates single points of failure. If one processor fails, the remaining three continue to operate, and the faulty processor is automatically bypassed. This minimizes downtime and ensures continuous protection for plant assets and personnel.

3. Flexible Integration with Existing Systems

Support for multiple communication protocols (Ethernet, Modbus, Profibus) allows the FC-QPP-0001 to integrate with legacy plant networks and third-party devices. This reduces the need for costly system overhauls and simplifies engineering.

4. Easy Diagnostics & Maintenance

Continuous self-diagnostics and real-time fault logging enable quick identification and resolution of issues. The module’s modular design allows for hot-swappable processor replacements, minimizing maintenance downtime.

Field Engineer’s Notes (From the Trenches)

When installing the FC-QPP-0001, always verify the redundant power supply configuration—the module requires two power modules (e.g., Honeywell PSU-24V) for full redundancy. I once saw a plant skip this step, leading to a complete system shutdown when one power supply failed.
Check the voting logic settings​ in the Safety Builder software—ensure that the 2oo4D mode is enabled. A misconfigured voting logic can cause the system to ignore valid faults or trigger spurious trips.
Use shielded twisted-pair (STP) cable​ for communication links—unshielded cable can pick up electromagnetic interference (EMI) from nearby equipment, leading to communication errors. I spent hours troubleshooting a “no data” fault only to find the cable was unshielded.

Real-World Applications

1. Chemical Plant Emergency Shutdown (ESD)

A Texas chemical plant uses the FC-QPP-0001 to control its ESD system. The module monitors pressure, temperature, and flow rates from 50+ field devices. If any parameter exceeds safe limits, the FC-QPP-0001 triggers an immediate shutdown, preventing a potential explosion. The QMR architecture ensures that the system remains operational even if one processor fails.

2. Oil Refinery Fire & Gas Detection

A Louisiana oil refinery uses the FC-QPP-0001 to integrate fire and gas detectors with the Safety Manager system. The module processes signals from 100+ detectors and sends alerts to the control room. The 2oo4D voting logic prevents false alarms, ensuring that only genuine threats trigger a response.

3. Power Generation Turbine Control

A California power plant uses the FC-QPP-0001 to control its gas turbine. The module monitors turbine speed, exhaust temperature, and fuel flow. If the speed exceeds 3000 RPM, the FC-QPP-0001 shuts down the turbine, preventing damage to the blades. The redundant design ensures that the turbine remains operational even during maintenance.