Description
Product Overview
The Emerson Ovation 5X00119G01 is an 8-channel RTD input module designed exclusively for Emerson’s Ovation Distributed Control System (DCS). It serves as a critical interface between the Ovation controller and RTD sensors (e.g., Pt100, Pt1000), enabling accurate temperature monitoring in industrial automation applications. As part of the Ovation ecosystem, the 5X00119G01 is widely used in industries where precise temperature control is essential, such as power generation, chemical processing, and manufacturing.
The 5X00119G01’s primary role is to convert resistance signals from RTD sensors to digital data for the Ovation controller, ensuring reliable temperature measurement even in harsh industrial environments. Its robust design (conformal coating for humidity/dust resistance) and high accuracy (±0.1°C) make it suitable for applications requiring long-term stability and minimal maintenance.
Key Technical Specifications
The 5X00119G01’s technical specifications are tailored for high-precision temperature measurement in industrial settings, with a focus on flexibility, reliability, and compatibility:
|
Parameter
|
Specification
|
|---|---|
|
RTD Types Supported
|
Pt100 (100Ω at 0°C), Pt1000 (1000Ω at 0°C), Ni120, Cu10 (2-wire/3-wire/4-wire configurable)
|
|
Temperature Range
|
-200°C to +850°C (depending on RTD type)
|
|
Accuracy
|
±0.1°C typical (at 25°C ambient); ±0.1% of reading (maximum)
|
|
Resolution
|
16-bit A/D conversion (0.01°C)
|
|
Isolation
|
3000V AC channel-to-channel (prevents cross-talk and surge damage)
|
|
Power Supply
|
24V DC nominal (±10% tolerance, compatible with Ovation system power)
|
|
Operating Temperature
|
-40°C to +85°C (IEC 60068-2 compliant, suitable for extreme environments)
|
|
Storage Temperature
|
-40°C to +104°C (withstanding extreme storage conditions)
|
|
Humidity Range
|
0–95% RH (non-condensing, resistant to moisture)
|
|
Update Rate
|
Configurable scan rates up to 10 Hz per channel (adapts to slow/fast process dynamics)
|
|
Dimensions
|
~100 mm × 80 mm × 50 mm (compact for cabinet installation)
|
|
Weight
|
~0.5 kg (1.1 lbs, lightweight for easy handling)
|
|
Certifications
|
CE, UL (compliant with international safety standards)
|

WESTINGHOUSE 1C31234G01
Field Application & Problem Solved
In industrial automation, temperature monitoring is critical for:
-
Process Optimization: Maintaining optimal temperatures for chemical reactions, power generation, or manufacturing processes.
-
Fault Detection: Identifying overheating equipment (e.g., motors, transformers) to prevent failures.
-
Safety: Ensuring compliance with safety regulations (e.g., boiler temperature limits in power plants).
The biggest challenge with legacy temperature measurement systems is inaccurate readings (due to sensor noise or poor signal conditioning) and limited compatibility (with only one RTD type). The 5X00119G01 solves this by:
-
Supporting Multiple RTD Types: It accepts Pt100, Pt1000, Ni120, and Cu10 RTDs, eliminating the need for multiple modules.
-
Providing High Accuracy: The ±0.1°C accuracy ensures reliable temperature data, even in high-noise environments.
-
Integrating with Ovation DCS: Seamless communication with the Ovation controller enables real-time adjustments and fault logging.
Typical Applications:
-
Power Generation: Monitoring boiler feedwater temperature, turbine exhaust temperature, and generator winding temperature.
-
Chemical Processing: Tracking reactor temperature, distillation column temperature, and pipeline fluid temperature.
-
Manufacturing: Measuring oven temperature, furnace temperature, and conveyor belt heating element temperature.
Installation & Maintenance Pitfalls (Expert Tips)
To ensure optimal performance and reliability, follow these best practices for installing and maintaining the 5X00119G01:
-
Verify RTD Compatibility:
-
Always confirm the RTD sensor’s type (e.g., Pt100 vs. Pt1000) and configure the 5X00119G01 accordingly. Mismatched configurations can lead to incorrect temperature readings.
-
Example: A client once experienced a 5% error in temperature readings because the module was configured for Pt100 instead of Pt1000.
-
-
Ensure Proper Wiring:
-
Use shielded twisted-pair cables for RTD connections to reduce electromagnetic interference (EMI). Avoid running cables alongside power lines—this is a classic cause of “ghost” temperature fluctuations.
-
Tip: Ground the cable’s shield at one end (preferably the module end) to ensure effective shielding.
-
-
Check Power Supply Stability:
-
The 5X00119G01 requires a stable 24V DC power supply (±10% tolerance). Use a multimeter to verify the power supply’s output before connecting the module—fluctuations can damage the module’s input circuitry.
-
-
Calibrate Annually:
-
Even though the 5X00119G01 has high accuracy, calibrate it annually using a precision RTD calibrator. Compare the module’s readings to the calibrator’s output—if the deviation exceeds ±0.1°C, recalibrate using Emerson’s calibration tool.
-
Case Study: A refinery avoided a process upset by detecting a 0.2°C error in the 5X00119G01’s readings, which was corrected through calibration.
WESTINGHOUSE 1C31234G01
-
Technical Deep Dive & Overview
The 5X00119G01 operates as part of the Ovation DCS architecture, which consists of:
-
Ovation Controller: Located in the central control room, it processes temperature data from the 5X00119G01 and sends commands to field devices.
-
5X00119G01 Module: Installed in a remote I/O node or control cabinet, it receives resistance signals from RTD sensors.
-
RTD Sensors: Attached to rotating equipment (e.g., turbine shafts) or process vessels, they generate resistance signals proportional to temperature.
How It Works:
-
The RTD sensor’s resistance changes with temperature (e.g., Pt100 has a resistance of 100Ω at 0°C and 138.5Ω at 100°C).
-
The 5X00119G01 receives the resistance signal and applies signal conditioning (e.g., filtering, amplification) to remove noise.
-
The module converts the conditioned resistance signal to a digital value (via a 16-bit ADC) and sends it to the Ovation controller via the Ovation network.
-
The Ovation controller uses the temperature data for process control (e.g., adjusting boiler fuel flow) or fault detection (e.g., triggering an alarm if temperature exceeds limits).
Key Advantages:
-
Compatibility: Works with all Ovation DCS controllers and RTD sensors.
-
Ruggedness: The conformal coating withstands dust, water, and vibration—ideal for harsh industrial environments.
-
Ease of Use: Software-configurable settings (e.g., RTD type, update rate) reduce commissioning time.
Final Notes
The Emerson Ovation 5X00119G01 is a reliable and essential component of the Ovation DCS, enabling high-precision temperature monitoring for industrial automation. Its compatibility with multiple RTD types, high accuracy, and rugged design make it ideal for mission-critical applications where temperature control is non-negotiable. Whether you’re upgrading a legacy system or building a new one, the 5X00119G01 will provide the accurate temperature data you need—just remember to follow the installation tips to avoid common pitfalls.