Non-Contact Design: Eliminates electrode fouling and polarization errors in dirty or corrosive media.
PFA Material: Superior chemical resistance for aggressive environments (vs. standard PEEK).
Wide Bore Design: Reduces fouling risk and ensures long-term stability in slurry or high-solid processes.
Wide Rangeability: Covers 6 decades of conductivity (1 µS/cm to 2 S/cm) for versatile applications.
Flexible Installation: Supports bulkhead, flange, or retractable (hot-tap) mounting (e.g., PR10 holder for maintenance without process shutdown).
Integrated Temperature Compensation: PT1000 sensor ensures accurate readings across -20°C to 130°C.
Manufacturer: Yokogawa Part number: ISC40G-TF-T1-05
Our extensive Yokogawa catalogue, including
: ISC40G-TF-T1-05
, is available now for dispatch to the worldwide.
The YOKOGAWA ISC40G-TF-T1-05 is an inductive (toroidal) conductivity sensor designed for harsh industrial environments, offering non-contact measurement to eliminate fouling, polarization, and corrosion issues. Part of Yokogawa’s ISC40 series, the ISC40G-TF-T1-05 features a PFA (Teflon) sensor body (TF suffix) for superior chemical resistance, making it suitable for aggressive media like hydrofluoric acid and oxidizing acids. With a measurement range of 1 µS/cm to 2 S/cm and ±0.5% of reading + 0.5 µS/cm accuracy, it supports real-time monitoring in applications such as brine concentration control, CIP (Clean-in-Place) systems, and slurry processing. The sensor includes a PT1000 temperature sensor (T1) and a 5-meter cable (05), enabling flexible installation in pipelines or tanks. Its rugged stainless steel mounting and bulkhead design ensure durability in high-pressure (up to 5 bar) and high-temperature (-20°C to 130°C) conditions.
2. Technical Parameters
Parameter
Specification
Type
Inductive (toroidal) conductivity sensor
Sensor Material
PFA (Teflon) for chemical resistance (TF suffix)
Measurement Range
1 µS/cm to 2 S/cm (6-decade range)
Accuracy
±0.5% of reading + 0.5 µS/cm
Temperature Range
-20°C to 130°C (process); -40°C to 150°C (storage)
Temperature Sensor
PT1000 (T1 suffix)
Cable Length
5 meters (05 suffix)
Pressure Rating
Up to 5 bar (72 psi)
Flow Bore Diameter
22 mm (wide bore for anti-fouling)
Mounting
Bulkhead, in-line, or retractable (via optional holders like PR10)
Chemical Resistance
Resistant to hydrofluoric acid, nitric acid, sulfuric acid, and oleum (PFA material)
Weight
1.3 kg (sensor); 2.5 kg (with accessories)
ISC40G-TF-T1-05
3. Advantages and Features
Non-Contact Design: Eliminates electrode fouling and polarization errors in dirty or corrosive media.
PFA Material: Superior chemical resistance for aggressive environments (vs. standard PEEK).
Wide Bore Design: Reduces fouling risk and ensures long-term stability in slurry or high-solid processes.
Wide Rangeability: Covers 6 decades of conductivity (1 µS/cm to 2 S/cm) for versatile applications.
Flexible Installation: Supports bulkhead, flange, or retractable (hot-tap) mounting (e.g., PR10 holder for maintenance without process shutdown).
Integrated Temperature Compensation: PT1000 sensor ensures accurate readings across -20°C to 130°C.
4. Application Areas and Cases
Industry Applications: Chemical processing, oil and gas, food and beverage, pharmaceuticals, water treatment.
Use Cases:
Brine Concentration Control: Monitors NaCl concentration in a food processing plant, achieving ±0.1% accuracy and reducing manual sampling by 80% (2024 case study).
CIP System Optimization: Measures cleaning solution strength in a pharmaceutical facility, cutting chemical waste by 30% through real-time conductivity feedback.
5. Competitor Comparison
Compared to traditional contact-type sensors:
No Fouling/Polarization: Non-contact design avoids electrode maintenance (vs. frequent cleaning in contact sensors).
Wider Chemical Resistance: PFA material handles hydrofluoric acid (vs. PEEK sensors limited to non-fluoride acids).
Longer Lifespan: 10+ years in corrosive environments (vs. 3–5 years for contact sensors in similar conditions).
ISC40G-TF-T1-05
6. Selection Recommendations
Material Choice: Use TF (PFA) for fluorinated acids; choose GG (PEEK) for non-aggressive media (e.g., brine).
Temperature Range: Verify process temperature (e.g., 130°C max for PFA vs. 180°C for PEEK).
Installation Type: Select holders (e.g., FF/FS/FH) based on pipe size (DN25–DN150) and maintenance needs (retractable PR10 for critical processes).
Cable Length: Opt for 05 (5m) for standard setups; customize lengths (01–10m) for remote installations.
7. Precautions
Installation: Ensure proper flow velocity (0.3–3 m/s) to prevent fouling; torque stainless steel fittings to 25–30 N·m.
Calibration: Use Yokogawa-certified standards (e.g., 1413 µS/cm solution) every 12–24 months.
Chemical Compatibility: Avoid use in pure water (ultra-low conductivity <1 µS/cm).
Safety: Disconnect power before servicing; follow IEC 61508 for SIL-rated applications.
声明: Shanxi Xinyeda International Trade Co., Ltd. is your trusted partner for YOKOGAWA ISC40G-TF-T1-05 and inductive conductivity solutions. We provide certified sensors, holders, and technical support for process optimization. Visit www.xydcontrol.com or contact us for custom industrial measurement solutions.
We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
Full 12-month warranty on all components
Dedicated after-sales support
Same-day dispatch on 1000s of parts
All units are fully tested
Continue Searching
We're here when you need us
What happens next?
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.