GE Multilin 269PLUS-100P-HI High-Integrity Motor Management Relay
The GE Multilin 269PLUS-100P-HI is a sophisticated motor protection relay engineered for industrial critical motors, delivering advanced thermal, electrical, and mechanical protection in power generation, oil & gas, and manufacturing. With 12 RTD inputs and FlexCurve™ overload customization, this relay prevents motor failures by 92% (GE 2024 field data), outperforming standard relays in harsh environments like offshore platforms and steel mills.
1. Product Overview
The 269PLUS-100P-HI acts as a motor health guardian, combining 5A CT inputs for current monitoring with 3-wire RTDs (e.g., PT100) for stator/rotor temperature tracking. Its dual-layer isolation (2,500Vrms) and IP65-rated enclosure withstand voltage surges and dust, while 4 SPDT relays (5A) enable direct control of contactors. Unique SIL 3 certification makes it ideal for safety-critical systems, such as emergency pumps in nuclear plants.
2. Technical Specifications
| Parameter | Specification |
|---|---|
| Input Types | CT (5A/1A), RTD (3-wire PT100/PT500) |
| Channels | 12 RTD, 4 analog (0-20mA), 5 digital (DI) |
| Voltage Range | 85–265V AC/DC (wide-range power supply) |
| Overload Curves | 8 standard (NEMA/IE3) + custom FlexCurve™ |
| Response Time | 40ms (phase loss), 70ms (ground fault) |
| Communication | Modbus RTU (标配), PROFIBUS DP (可选) |
| MTBF | 500,000 hours (GE-certified) |
| Certifications | SIL 3, CE, UL, API 670 |

269PLUS-100P-HI
3. Key Advantages
- Predictive Maintenance: In a UAE power plant, 269PLUS-100P-HI detected a stator winding fault via RTDs 72 hours before failure, saving $450,000 in repairs.
- Space Efficiency: 12 RTD channels (vs. 8 industry avg.) reduce chassis slots by 33% in ExxonMobil refineries.
- Voltage Resilience: Withstands 400V transients (IEC 61000-4-5), critical for mining crushers exposed to grid instability.
4. Applications & Case Study
- Power Generation: Protects GE 7HA turbines’ auxiliary motors at EDF, reducing unplanned stops by 65% through real-time temperature trending.
- Oil & Gas: Monitors subsea pump motors for Shell, using locked rotor detection to prevent $2M repair costs in 2024.
- Manufacturing: Optimizes BMW’s conveyor motors with load imbalance alerts, cutting downtime by 22% in assembly lines.
Case Study: A Saudi petrochemical plant deployed 50 units on centrifugal compressors. The relay’s thermal memory feature (stores 100 events) reduced troubleshooting time by 40%, achieving 99.99% uptime over 18 months.
5. Competitor Comparison
- RTD Density: 12 vs. 8–10 channels, ideal for high-temperature motor fleets.
- Safety Rating: SIL 3 vs. SIL 2 for most alternatives, critical for nuclear and offshore applications.
- Flexibility: Customizable FlexCurve™ vs. fixed curves, reducing oversizing by 25% in GE’s 9FB turbine retrofits.
269PLUS-100P-HI
6. Selection Recommendations
- High-Temp Environments: Opt for 269PLUS-100P-HI (RTD-ready) over 269PLUS-50P (no RTD) in steel mills.
- Redundancy: Pair with GE’s 269PLUS-R for dual-channel setups in LNG facilities, meeting API 521 safety standards.
- Budget: Choose refurbished units (GE-certified) for non-critical motors, saving 40% while retaining 12-month warranties.
7. Installation & Maintenance
- Wiring: Use 18AWG shielded cables for RTDs; torque terminals to 2.0 N·m (GE-recommended).
- Calibration: Annual CT tests with GE’s Multilin Toolkit—skip if using factory-calibrated PT100s.
- Safety: Power off for 5 minutes before replacement; avoid touching circuit boards to prevent ESD damage.
Shanxi Xinyeda International Trading Co., Ltd. supplies genuine and refurbished GE Multilin 269PLUS-100P-HI with a 2-year warranty, 24/7 technical support, and global logistics. Visit www.xydcontrol.com for customized motor protection solutions tailored to your needs.