High Reliability: TMR redundancy (contact variant) ensures fault tolerance, with automatic fail-safe mode and diagnostic monitoring (e.g., voltage drop detection <40% nominal).
The GE HE700GEN200 is a versatile industrial control module designed for mission-critical applications in VME-based systems, Mark VI/VIe turbine controls, and industrial automation. Available in two variants—contact input module and VME interface module—it bridges the gap between field devices and control systems. The contact input variant offers 24 isolated dry contact inputs with surge protection and noise filtering, ideal for turbine control and machinery monitoring. The interface variant supports Gen-2 NVMe communication and VME 背板 integration, enabling high-speed data transfer in data centers and high-performance computing. With robust reliability features like TMR (Triple Modular Redundancy) support and modular design, the HE700GEN200 ensures seamless integration and long-term operational stability.
2. Product Parameters
Parameter
Contact Input Variant
VME Interface Variant
Brand
GE
GE
Model
HE700GEN200
HE700GEN200
Voltage
24V DC (nominal)
220V (variant-dependent)
Channels
24 dry contact inputs
N/A (interface-only)
Communication
Genius network, VME 背板
VME 背板,Gen-2 NVMe
Redundancy
Single/TMR (Triple Modular Redundancy)
N/A
Protection
Surge protection, noise filtering
ESD protection, thermal regulation
Mounting
VME rack-mounted (Mark VI compatible)
VME rack-mounted
Environment
0°C–60°C (operation), -40°C–85°C (storage)
Same as contact variant
Certifications
CE (select models)
CE (select models)
HE700GEN200
3. Advantages and Features
High Reliability: TMR redundancy (contact variant) ensures fault tolerance, with automatic fail-safe mode and diagnostic monitoring (e.g., voltage drop detection <40% nominal).
Versatile Compatibility: Works with GE’s Mark VI/VIe turbines, RX3I PAC systems, and third-party OPC UA devices.
Noise Immunity: Built-in 4ms hardware filters and surge protection (contact variant) ensure stable operation in harsh environments.
Flexible Configuration: DIP switches (interface variant) enable custom settings for Gen-2 NVMe devices or Genius network protocols.
4. Application Areas and Case Studies
Energy Sector: Turbine control systems (Mark VI/VIe) for dry contact signal acquisition (e.g., valve status, sensor inputs).
Industrial Automation: VME system I/O expansion in manufacturing (CNC machines, production lines).
Data Centers: High-speed NVMe storage integration (interface variant) for low-latency data processing.
Case Study: A European power plant upgraded its Mark VI turbine control system with GE HE700GEN200 contact modules. The 24-channel TMR configuration reduced downtime by 30% by isolating faulty inputs and triggering fail-safe modes, ensuring continuous operation during component failures.
5. Competitive Comparison
Compared to similar industrial I/O modules, the HE700GEN200 stands out with:
Native GE Ecosystem Integration: Optimized for GE’s Mark VI/VIe and RX3I systems, reducing compatibility issues.
Dual Variant Flexibility: Combines contact input (24-channel isolation) and interface (NVMe/VME) capabilities in a single form factor.
Redundancy Depth: TMR support (contact variant) surpasses standard single/dual redundancy solutions, enhancing safety-critical applications.
HE700GEN200
6. Selection Recommendations
Voltage Matching: Confirm system voltage (24V DC for contact inputs; 220V for interface variants).
Redundancy Needs: Choose TMR variant for safety-critical systems (e.g., turbines, aerospace).
Environment: Ensure temperature range (0°C–60°C operation) matches industrial settings.
Compatibility: Verify VME 背板 or Genius network compatibility with existing GE or third-party systems.
7. Precautions
Installation: Align modules carefully in VME racks to avoid connector damage. Use ESD-protective gear during handling.
Maintenance: Regularly inspect terminal block connections; replace corroded terminals. Monitor diagnostic alerts for voltage irregularities.
Redundancy Setup: In TMR systems, ensure all three modules (JR1, JS1, JT1 connectors) are synchronized for consistent voting.
Voltage Stability: Use regulated power supplies (±10% tolerance) to prevent performance degradation.
声明: Shanxi Xinyeda International Trade Co., Ltd. is your trusted partner for GE HE700GEN200 and other automation spare parts. We provide sales and technical support—visit www.xydcontrol.com or contact us for tailored solutions.
We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
Full 12-month warranty on all components
Dedicated after-sales support
Same-day dispatch on 1000s of parts
All units are fully tested
Continue Searching
We're here when you need us
What happens next?
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.