Expansion Capacity: 4 or 7 Expander Chassis (T8312-4 / T8312-7)
Connector Type: 12-pin ODU connectors (4 or 7 ports)
Backplane Interface: 96-way C type connector
Operating Voltage: 220V AC/DC
Power Consumption: 6W
Operating Temperature: -40°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity Range: 5% to 95% RH (non-condensing)
Dimensions: 133mm × 133mm × 63mm
Weight: 1.2kg
Isolation: Fully shielded for EMC protection
Certification: CE, UL, ATEX
ICS Triplex PS01-B
Field Application & Problem Solved
In safety-critical industrial environments like oil refineries and power plants, the biggest challenge is scaling control systems while maintaining triple modular redundancy and fault tolerance. The T8312 solves this by providing a robust interface that allows seamless expansion of the Trusted TMR system from the Controller Chassis to multiple Expander Chassis without compromising system integrity or safety certification.You’ll typically find this module deployed in emergency shutdown systems (ESD), fire and gas detection systems, and turbine protection applications where system expansion is required beyond the base controller capacity. In oil and gas facilities, it enables the connection of additional I/O modules for monitoring critical process parameters, safety interlocks, and emergency shutdown valves. The module’s core value lies in its ability to maintain the TMR architecture across expanded chassis, ensuring that even if one channel or processor fails, the system continues to operate with the remaining two channels, preventing catastrophic failures in mission-critical applications.The T8312’s fully shielded design and EMC protection ensure reliable operation in electrically noisy industrial environments, while its wide operating temperature range (-40°C to +70°C) and ATEX certification make it suitable for deployment in hazardous locations where explosive atmospheres require intrinsically safe equipment. The module’s locking connectors provide secure connections that prevent accidental disconnection during operation, a critical feature in environments subject to vibration and mechanical stress.
Installation & Maintenance Pitfalls (Expert Tips)
Chassis ID Configuration is Critical: The most common mistake I see in the field is improper ID switch configuration on Expander Chassis. Each chassis must have its three ID switches configured to address 2,3,4…8 sequentially. If more than eight chassis are needed, a second Expander Interface is required, and the virtual addresses must be set to 9,10,11…15 in the System.INI configuration. Incorrect addressing will cause communication failures and prevent the system from recognizing the expanded I/O points.Power Supply Verification Before Installation: Before connecting the T8312, verify that the power supply matches the module’s 220V AC/DC requirement. Use a calibrated multimeter to check voltage at the terminal block, not just at the power supply output. Ensure the total current draw of all connected chassis doesn’t exceed the power supply capacity, and verify that all field devices are rated for the same voltage.Grounding and Shielding Practices: While the module is fully shielded for EMC protection, improper shield grounding can still introduce noise that causes intermittent communication failures. Field wiring shields should be grounded at only one end (typically at the control system end) to prevent ground loops. Maintain at least 6 inches of separation between signal cables and power cables, and use twisted pair cables for noise immunity.Connector Locking Mechanism: Don’t ignore the locking connectors on the T8312. These connectors must be properly engaged and locked to ensure secure connections that won’t vibrate loose in industrial environments. After installation, perform a tug test on all connections to verify they’re secure. The release button on the module should only be used during maintenance or replacement, not during normal operation.Firmware and Configuration Backup: Always back up the system configuration before installing or replacing the T8312 module. The module stores configuration data that must match the system settings. Use the manufacturer’s configuration tool to export the current configuration to a secure location before making any changes. Verify firmware version compatibility between the T8312 and the Trusted TMR system before installation.
ICS Triplex PS01-B
Technical Deep Dive & Overview
The ICS Triplex T8312 is a Trusted TMR Expander Interface Adapter Unit designed to provide interconnection between the Trusted Expander Interface Modules in the Controller Chassis and multiple Expander Chassis. The module employs a Triple Modular Redundancy (TMR) architecture that provides three independent signal paths for each connection, ensuring continuous operation even if one channel fails.From a technical perspective, the T8312 comprises either four or seven 12-pin ODU connectors (depending on the version), a printed circuit board (PCB), and a 96-way C type connector that plugs into a double 96-way connector assembly designed to connect to the Trusted Expander Interface Modules in the Controller Chassis. The unit is contained within a metal enclosure and is designed to be clipped onto the Controller Chassis rear connectors, with a release button provided for disconnection during maintenance.The module functions by providing a fault-tolerant communication path between the main processor and the expanded I/O modules in the Expander Chassis. Each Expander Chassis is assigned a unique address (2,3,4…8) that corresponds to its virtual address in the system configuration. The TMR architecture ensures that data is transmitted and received across three independent channels, with voting mechanisms that automatically isolate faulty channels while maintaining system operation with the remaining two channels.The T8312’s fully shielded design provides electromagnetic compatibility (EMC) protection, preventing electrical noise from interfering with critical control signals. The module’s wide operating temperature range and ATEX certification make it suitable for deployment in harsh industrial environments where reliability and safety are non-negotiable requirements.
We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
Full 12-month warranty on all components
Dedicated after-sales support
Same-day dispatch on 1000s of parts
All units are fully tested
Continue Searching
We're here when you need us
What happens next?
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.