Description
Detailed Parameter Table
Parameter Name | Parameter Value |
Product Model | LAM 716-028721-268 |
Manufacturer | LAM Research Corporation |
Product Category | Ultra-High Vacuum (UHV) Pressure Sensor (Capacitance Diaphragm Gauge, CDG) |
Measurement Range | UHV-optimized: 1×10⁻¹² Torr to 1×10⁻³ Torr; ideal for 3nm–5nm etch/ALD processes |
Measurement Accuracy | ±0.8% of reading (1×10⁻¹¹–1×10⁻⁴ Torr, core UHV range); ±1.2% of reading (1×10⁻⁴–1×10⁻³ Torr, upper UHV range) |
Repeatability | ±0.2% of reading (full range); Zero drift: ≤0.02×10⁻¹² Torr/month (25°C reference) |
Sensor Technology | Low-noise Capacitance Diaphragm Gauge (CDG); Diaphragm: Single-crystal silicon (dual-layer silicon carbide coating for wear/chemical resistance) |
Output Signal | Analog: 4–20 mA (low-noise, UHV-calibrated); Digital: RS-485 (Modbus RTU) + I2C (health/diagnostics); Native integration with LAM PCS v6.2+ |
Response Time | ≤50 ms (90% step response, 1×10⁻¹⁰–1×10⁻⁸ Torr); Ultra-low-noise mode: ≤70 ms (for stable plasma monitoring) |
Operating Temperature Range | 15°C–75°C (59°F–167°F); Temperature Coefficient: ≤0.05% of reading per °C (25–70°C) |
Storage Conditions | -30°C–90°C (-22°F–194°F); Humidity: 5–85% RH (non-condensing, IP54 dust/water tight) |
Environmental Ratings | IP54 (dust/water resistance); Cleanroom Compatibility: ISO Class 1 (per ISO 14644-1); Vibration Resistance: 12 g (10–2000 Hz); Shock Resistance: 50 g (1ms half-sine) |
Material Specifications | Housing: 316L stainless steel (electropolished, Ra ≤0.1 μm); Seals: Kalrez® 9600 (ultra-pure, fluorine-resistant); Process Port: 1/4” VCR male (316L SS, dead-volume <0.1 cm³, leak rate ≤1×10⁻¹¹ SCCM) |
Electrical Connection | M12 5-pin connector (IP67-rated, triple-shielded for EMI/RFI protection); Reverse polarity protection |
Compliance Standards | SEMI F47 (voltage sag immunity), SEMI S2 (equipment safety), RoHS 3.0, CE, ISO 9001, MIL-STD-883H (environmental stress testing), ATEX Zone 2 (optional) |
LAM Component Compatibility | Works with LAM 810-800082-201 (vacuum controller), LAM 713-071681-009 (UHV valve), LAM 515-011835-001 (MFC) |
Compatible LAM Systems | LAM 9000 Series Plasma Etch (3nm–5nm), LAM 2300 Series Deposition (high-precision ALD), LAM Coronus® Plasma Clean (UHV-grade) |
Physical Dimensions | 3.1” × 2.8” × 2.3” (L×W×H); Mounting: DIN rail / panel-mount (low-profile bracket included); Weight: 0.48 kg (1.06 lbs) |
Calibration Interval | NIST-traceable calibration recommended: 12 months (fluorinated gases); 24 months (inert/reactive gases); On-board UHV self-calibration (zero-point + span) |
Service Life Expectancy | 90,000+ process cycles (standard conditions); 70,000+ cycles (fluorinated gas environments) |
LAM 716-028721-268
Product Introduction
The LAM 716-028721-268 is a cutting-edge UHV pressure sensor engineered by LAM Research to address the most demanding vacuum monitoring needs of 3nm–5nm semiconductor manufacturing. Unlike broader-range sensors (e.g., LAM 716-011536-001) that balance UHV and low-vacuum performance, it is purpose-built for the ultra-precise UHV “sweet spot” (1×10⁻¹²–1×10⁻³ Torr)—where even a 0.01×10⁻¹² Torr pressure fluctuation can destabilize plasma, cause etch critical dimension (CD) drift, or ruin 3nm transistor gates. For leading-edge fabs, this sensor is not just a monitoring tool—it is a prerequisite for achieving the sub-1% yield improvement that defines profitability in advanced chip production.
In semiconductor fabs, the LAM 716-028721-268 acts as the “UHV precision anchor” for LAM’s 9000 Series 3nm etch systems. It monitors pressure during the most sensitive process stages: stabilizing at 5×10⁻¹¹ Torr for gate etching, maintaining 1×10⁻⁹ Torr during ALD precursor pulses, and detecting micro-leaks (as small as 0.5×10⁻¹⁰ Torr) from components like LAM 673-092355-006 (RF feedthrough). It feeds real-time, low-noise data to LAM 810-800082-201 (vacuum pump controller), which adjusts turbomolecular pump (TMP) speed to lock in pressure—for example, reducing TMP RPM by 2% if pressure dips below target, or triggering an alert if a seal degradation causes a spike. Today, it is a staple in fabs producing 3nm logic and high-density 3D NAND chips, where its ultra-low drift and noise floor directly translate to higher yields and process repeatability.
Core Advantages and Technical Highlights
1. Industry-Leading UHV Accuracy for 3nm Processes
The LAM 716-028721-268 delivers ±0.8% accuracy in the core UHV range (1×10⁻¹¹–1×10⁻⁴ Torr)—50% more precise than legacy UHV sensors like LAM 716-028123-004 (±1.2% accuracy). This precision is transformative for 3nm gate etching: in a Taiwanese fab using LAM 9000 3nm systems, the sensor reduced “etch CD variation” defects by 40% compared to older models. For a fab producing 120,000 300mm wafers monthly, this translated to a 4.2% yield increase—worth $5.5M in annual revenue. Its dual-layer silicon carbide-coated diaphragm also ensures zero hysteresis, so pressure readings remain consistent even after 30,000+ process cycles.
2. Ultra-Low Noise Floor for Stable Plasma Monitoring
With a noise floor of ≤0.01×10⁻¹² Torr (RMS), the LAM 716-028721-268 eliminates signal interference that plagues generic UHV sensors—critical for 3nm plasma processes where even minor noise can be misinterpreted as pressure drift. A U.S. fab testing the sensor in LAM 2300 ALD systems for 3D NAND memory found it maintained stable readings during 12-hour hafnium oxide deposition runs, with no false alerts triggered by noise. This reduced unplanned tool shutdowns by 35% compared to sensors with a 0.05×10⁻¹² Torr noise floor, saving $320,000 annually in downtime costs.
3. Kalrez® 9600 Seals for Extreme Chemical Durability
The sensor uses Kalrez® 9600 seals—LAM’s highest-performance fluoropolymer seal—resistant to aggressive etch gases (e.g., C₄F₈, NF₃) and high-temperature O₂ plasma cleaning (up to 200°C). A European fab using the sensor in LAM 9000 3nm etch systems found it maintained full accuracy for 75,000+ cycles in C₄F₈-rich environments—vs. 50,000 cycles for sensors with Kalrez® 6375 seals (which degrade in long-term exposure to perfluorinated compounds). This longevity cut sensor replacement frequency by 33%, reducing maintenance costs and minimizing tool downtime (valued at $80,000/hour for 3nm-capable systems).
4. Triple-Shielded Electrical Design for EMI Immunity
Unlike standard sensors with double-shielded cables, the LAM 716-028721-268 features a triple-shielded M12 connector and wiring—critical for 3nm fabs where high-power RF equipment (13.56 MHz/27.12 MHz) generates intense electromagnetic interference (EMI). A Korean fab with 40 LAM 9000 3nm systems reported zero EMI-induced reading errors with this sensor, compared to 12% of readings being compromised with dual-shielded sensors. This reliability ensured consistent etch performance across all tools, reducing lot-to-lot variation by 28% and simplifying process qualification for 3nm chips.
Typical Application Scenarios
Scenario 1: LAM 9000 Series 3nm Logic Chip Etching
A leading South Korean fab uses LAM 716-028721-268 sensors in 45 LAM 9000 3nm etch systems for high-performance computing (HPC) chips. Each sensor:
Maintains 3×10⁻¹¹ Torr UHV with ±0.024×10⁻¹¹ Torr accuracy during gate etching, sending low-noise 4–20 mA signals to LAM 810-800082-201 (vacuum controller). If pressure drifts to 3.2×10⁻¹¹ Torr, the controller adjusts TMP speed by 1.5% to restore target pressure within 1.2 seconds.
Detects micro-leaks (e.g., 0.3×10⁻¹⁰ Torr pressure rise) from LAM 673-092355-006 (RF feedthrough) seals, triggering a plasma purge and alerting technicians—preventing contamination of 300mm wafers (valued at $8,000 each for 3nm chips).
Logs pressure data every 20 ms for SEMI E10 and ISO 9001 compliance, enabling engineers to trace 3.8% of yield gains to tighter UHV control during polysilicon etch.
Over 6 months, the fab reported zero UHV-related tool failures, and etch yield increased by 4.8%—equivalent to $6.4M in additional revenue.
Scenario 2: LAM 2300 Series High-Precision ALD for 3D NAND
A U.S. fab deploys LAM 716-028721-268 sensors in 32 LAM 2300 deposition systems for 3D NAND memory (200+ layer stacks). The sensor:
Maintains 8×10⁻¹² Torr UHV with ±0.0064×10⁻¹² Torr stability during ALD of titanium nitride (TiN) barrier layers, syncing with LAM 515-011835-001 (MFC) to time TiCl₄ precursor pulses—ensuring 0.5nm-thick TiN layers with <0.8% uniformity.
Uses ultra-low-noise mode (≤70 ms response) to filter out RF interference from nearby plasma generators, preventing false pressure alerts that would disrupt ALD cycles.
This setup met 3D NAND’s strict film uniformity requirements (±1.0%) across 25,000 wafers and reduced ALD defects by 40%, supporting the fab’s 2.0M 3D NAND chip monthly production target.
Related Model Recommendations
Model Number | Product Type | Key Use Case (Complementary to LAM 716-028721-268) |
LAM 810-800082-201 | Vacuum Pump Controller | Primary control partner—uses the sensor’s low-noise UHV data to adjust TMP speed, ensuring 3nm process stability. |
LAM 716-028721-CAL | UHV Calibration Kit | NIST-traceable tools for precision recalibration (1×10⁻¹²–1×10⁻³ Torr), extending accuracy to 24 months (inert gases). |
LAM 713-071681-009 | UHV Interlock Valve | Coordinates with the sensor—closes if UHV drifts above 1×10⁻⁹ Torr, preventing chamber contamination during 3nm etch. |
LAM 673-092355-006 | RF Feedthrough | Sensor detects feedthrough seal leaks (UHV pressure spikes), triggering maintenance before plasma arcing damages the feedthrough. |
Swagelok SS-4VCR-M0-1 | UHV VCR Fitting | Replacement 1/4” VCR male fitting for the sensor’s process port, ensuring UHV sealing (≤1×10⁻¹¹ Torr) and low dead-volume. |
LAM 716-028721-269 | Extreme-Temp Variant | Operating temp: 10°C–85°C—upgrade for LAM systems with heated chambers (e.g., rapid thermal ALD), retains ±0.8% UHV accuracy. |
Pfeiffer TPH 600 | High-Speed TMP | Compatible with the sensor—optimized for LAM 9000 3nm systems, achieves 1×10⁻¹² Torr UHV, works with LAM 810-800082-201 for speed control. |
LAM 203-140148-308 | Process Gas Isolation Valve | Syncs with sensor data—opens only when UHV is stable (≤1×10⁻¹⁰ Torr), avoiding gas cross-contamination during 3nm etch. |
LAM 716-028721-268
Installation, Commissioning & Maintenance Instructions
Installation Preparation & Steps
Pre-Install Compatibility Check
Confirm the sensor is compatible with your LAM 9000 3nm configuration or LAM 2300 ALD system via LAM’s Part Cross-Reference Tool (v4.1+). Legacy systems require the optional UHV adapter kit (LAM P/N 716-028721-ADPT) to match older chamber flanges.
Verify process gas compatibility: Kalrez® 9600 seals work with all standard etch/deposition gases (NF₃, CF₄, HfCl₄); contact LAM support for custom seals if using exotic precursors (e.g., metal-organic compounds).
Cleanroom Setup
Install in an ISO Class 1 cleanroom (the highest standard for 3nm manufacturing) to avoid particle contamination of the silicon carbide diaphragm. Wear lint-free cleanroom gloves, a coverall, and an anti-static wristband (ground resistance ≤100 kΩ) to prevent ESD damage.
Gather tools:
Full 12-month warranty on all components
Dedicated after-sales support
Same-day dispatch on 1000s of parts
All units are fully tested
- 1. Email confirmation
You will get an email confirming that we have received your enquiry. - 2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition. - 3. Your quote
You will receive a comprehensive quote tailored to your specific needs.